Dynamic Temperature Control Systems – LNEYA Air cooled chiller or Water cooled chiller https://www.lneya.com/it Industrial Chillers & Freezers Manufacturer, Dynamic Temperature Control Systems - LNEYA Wed, 20 Mar 2024 06:24:46 +0000 it-IT hourly 1 https://wordpress.org/?v=6.4.3 https://www.lneya.com/wp-content/uploads/2023/05/Lneya-logo-e1683777581854-150x137.png Dynamic Temperature Control Systems – LNEYA Air cooled chiller or Water cooled chiller https://www.lneya.com/it 32 32 MD -75℃~225℃ https://it.lneya.com/special-chiller/component-test-temp-control-systems/thermal-chuck-md.html https://it.lneya.com/special-chiller/component-test-temp-control-systems/thermal-chuck-md.html#respond Wed, 20 Mar 2024 06:05:00 +0000 https://www.lneya.com/?p=7627
MD -75℃~225℃

Thermal Chuck or Thermal Plate/Thermal Control Unit

MD -75℃~225℃
  • Precisione della temperatura±0.1℃
  • Potenza di riscaldamento-60°C to +25°C: 2 min 0°C to +25°C: 2 min +25°C to +220°C: 6 min
  • Potenza di raffreddamento220°C to +25°C: 2 min +25°C to -60°C: 6 min
  • Source Power2,8KW
  • Flat ShapeRound/Square

Modello

MD-708

MD-712

MDL-708

Temperatura. Intervallo

-75℃~225℃

-75℃~225℃

-75℃~225℃

Precisione del controllo della temperatura

±0.1℃

±0.1℃

±0.1℃

temperature uniformity

±1℃

±1℃

±1℃

Flatness

±50um

±50um

±50um

Tablet Size

200mm diameter disc

300mm diameter disc

150mm*200mm

Host and card cable

2.5m (other lengths can be customized)

Flat surface treatment

Electroplated nickel (optional gold plating)

Heat Up

-60°C to +25°C: 2 min

0°C to +25°C: 2 min

+25°C to +220°C: 6 min

Cool Down

220°C to +25°C: 2 min

+25°C to -60°C: 6 min

Sistema di controllo

PLC controller, heating feed-forward PID fuzzy algorithm, cooling electronic expansion valve PID adjustment control cooling capacity

Display and Record

7-inch color touch screen, record temperature curve

Comunicazione

Interfaccia Ethernet Protocollo TCP/IP

Refrigeration Compressors

Taikang

Alimentazione

220V 50/60HZ 2.8KW

220V 50/60HZ 4.5KW

220V 50/60HZ 2.8KW

Host size mm

550×650×370

550×650×370

550×650×370

MD’s greatest innovation in thermal testing is the series of thermally controlled chucks, which are mainly used for performance testing, modeling, process development, design defect or IC failure analysis of semiconductor wafers. It can realize rapid temperature change and precisely control the temperature. The system itself has its own refrigerator, which avoids the consumption of liquid nitrogen, carbon dioxide, etc., and each system includes a chuck and a cold and hot control unit.

The inside of the plate adopts the direct evaporation method of refrigerant, which greatly improves the heat exchange efficiency and the heat exchange power per unit area of the plate compared with the liquid cooling method.


Caratteristiche:
Rapid cooling/heating rates up to 25°C/min
Built-in refrigerator to avoid the consumption of liquid nitrogen, carbon dioxide, etc. Programmable automation, temperature stability +/-0.1
Controller provides touch screen and remote interface to precisely control and monitor equipment temperature
Display test status – real-time data

Thermal Chuck MD series provides an open flat surface working platform, rapid temperature rise and fall, and constant temperature control, which can be used for testing RF devices and high-density power devices (IGBTSAND MOSFETS), and can also be used for rapid cooling of laboratory flat panels (plasma, biological products, batteries), etc.

Invia per la consultazione

*
*
正在提交!
提交成功!
提交失败!
邮箱错误!
电话错误!
]]>
https://it.lneya.com/special-chiller/component-test-temp-control-systems/thermal-chuck-md.html/feed 0
YQH 0℃~-75℃ https://it.lneya.com/special-chiller/component-test-temp-control-systems/vocs-yqh-0-75.html https://it.lneya.com/special-chiller/component-test-temp-control-systems/vocs-yqh-0-75.html#respond Tue, 27 Feb 2024 07:46:10 +0000 https://www.lneya.com/?p=7077
YQH 0℃~-75℃

YQH 0℃~-75℃

Cattura e recupero della condensazione dei gas di scarico;Purificazione dei gas di scarico dei semiconduttori
  • Pressione della zona fredda8 Bar
  • Acqua di raffreddamento @25℃1300L/H~3000L/H 1BAR~4BAR
  • Potenza3kW~8kW

Download dei dati del prodotto

Modello

YQH-3520EXd

YQH-3520Wexd

YQH-7520EXd

YQH-7520WEXd

YQH-3530EXd

YQH-3530WEXd

YQH-7530EXd

YQH-7530WEXd

Flusso di gas

20m3/h

20m3/h

30m3/h

30m3/h

Temperatura più bassa

-35℃

-75℃

-35℃

-75℃

Temperatura del primo livello

0℃

0℃

0℃

0℃

Pressione della cella frigorifera

8bar

8bar

8bar

8bar

Area di scambio termico

3m2*2

3m2*2

5m2*2

5m2*2

Materiale dello scambiatore di calore

SUS304

SUS304

SUS304

SUS304

Monitoraggio della pressione

Monitoraggio e protezione della pressione di blocco antighiaccio per l'ingresso e l'uscita delle trappole di evaporazione primarie e secondarie

Controllo dello sbrinamento

Il controllo dello sbrinamento può essere effettuato in base al monitoraggio della pressione.

Diametro ingresso aria

DN40 PN16

DN40 PN16

DN50 PN16

DN50 PN16

Serbatoio di stoccaggio dei liquidi di recupero

10L Installazione opzionale della pompa di trasferimento a recupero

15L Installazione opzionale della pompa di trasferimento a recupero

Diametro dell'attacco di drenaggio

G1/2

G1/2

G1/2

G1/2

Sistema di controllo

PLC Siemens

Visualizzazione e registrazione

Schermo tattile a colori da 7 pollici

Compressore

Compressore flessibile Emerson Copeland Scroll (antideflagrante e incapsulato in resina epossidica)

Alimentazione 380V 50HZ MAX

3,5KW  

5KW

4KW

6KW

Dimensione

800*1200*1850

800*1200*1850

1000*1500*1850

1000*1500*1850

Acqua di raffreddamento (raffreddamento ad acqua)20

1800L/H 1BAR~4BAR G3/4

3000L/H 1BAR~4BAR G3/4

Inviaci un messaggio sul prodotto Vocs
Inviaci un messaggio sul prodotto Vocs
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

consigliare i prodotti

caricamento...

已经是到最后一篇内容了!

]]>
https://it.lneya.com/special-chiller/component-test-temp-control-systems/vocs-yqh-0-75.html/feed 0
Camera di gestione termica per il test della batteria https://it.lneya.com/special-chiller/cooling-heating-temperature-control-flow-system/battery-test-chamber.html https://it.lneya.com/special-chiller/cooling-heating-temperature-control-flow-system/battery-test-chamber.html#respond Mon, 26 Feb 2024 06:08:34 +0000 https://www.lneya.com/?p=6997
Camera di gestione termica per il test della batteria

KRYCH -40℃~100℃

Controllo del flusso di temperatura + camera di prova

Camera ambientale Fornisce -45°C~100°C

Download dei dati del prodotto

Il sistema integrato fornisce nuovi campioni di batterie energetiche
Alta temperatura, bassa temperatura, controllo di flusso e pressione e altre esigenze

Alta densità di scambio termico

Ingombro ridotto

Assicurarsi che la temperatura del nucleo della batteria sia bassa

Migliore uniformità

Prolungare efficacemente la durata della batteria

Migliorare l'affidabilità e la sicurezza

Riduzione dei costi di manutenzione

Parametro

Modello KRYCH-15W
KRYCH-15
Controllo della temperatura -40℃~135℃ Antigelo -45℃~100℃ Camera di prova
Controllo del flusso di antigelo 2L/min~20L/min ±0,2L/min
Pressione dell'antigelo Misurare e visualizzare la pressione in ingresso e in uscita e visualizzare la pressione sul touch screen
Volume della camera di prova cm 100*100*100 1m3
Potenza di riscaldamento 7,5kW Antigelo 5kW Camera di prova
Capacità di refrigerazione
Antigelo
135℃ 7,5kW
20℃ 7,5kW
0℃ 7,5kW
-20℃ 4,5kW
-30℃ 2,5kW
-35℃ 1,8kW
Capacità di refrigerazione
Camera di prova
100℃ 6kW
-20℃ 3,5kW
-40℃ 1,2kW
Precisione del controllo della temperatura dell'antigelo ±0.3℃
Camera di tempe alta e bassa Controllo di tempe ±0.3℃
Circolazione dell'aria all'interno della camera di prova 3500m3/h
Quando la porta viene aperta, la ventola di circolazione interna si spegne automaticamente e lo stato di apertura della porta viene visualizzato sul touch screen.
Controllore Controllore PLC, algoritmo di controllo fuzzy PID
Lettera di accordo Interfaccia Ethernet Protocollo TCP/IP
Feedback della temperatura interna del dispositivo Temperatura interna del serbatoio dell'apparecchiatura, temperatura di condensazione del sistema di refrigerazione, temperatura di aspirazione del compressore, temperatura dell'acqua di raffreddamento (per le apparecchiature di raffreddamento ad acqua)
Riscaldamento Si riferisce alla potenza massima di riscaldamento del sistema (a seconda dei modelli).
Il riscaldatore è dotato di una tripla protezione e di un limitatore di temperatura indipendente per garantire la sicurezza del sistema di riscaldamento;
La potenza di riscaldamento di 15kW utilizza un regolatore di tensione e il controllo della potenza di riscaldamento in uscita adotta un controllo lineare 4~20mA.
Capacità di raffreddamento Si riferisce alla capacità di sottrarre calore a diverse temperature (in condizioni ideali). Le condizioni di lavoro reali devono tenere conto della dissipazione del calore ambientale. Si prega di amplificare in modo appropriato e di adottare misure di isolamento.
Modulo di raffreddamento ad alta temperatura Può raffreddare il modulo dalla temperatura elevata di 150℃
Portata e pressione della pompa di circolazione Utilizzo della pompa a trascinamento magnetico LNEYA
Fonte 380V50HZ 23kW max
Dimensioni complessive cm 125*235*190 escluse le parti sporgenti, raffreddate ad aria e ad acqua hanno le stesse dimensioni
Compressore Compressore flessibile scroll Emerson Copeland
Evaporatore Scambiatore di calore a piastre
Accessori per la refrigerazione Filtri essiccatori, separatori d'olio, ecc. di marca Emerson/Danfoss.
Metodo dell'acceleratore Valvola di espansione elettronica
Pannello operativo Schermo tattile a colori da 7 pollici, visualizzazione della curva di temperatura
Sicurezza Dispone di funzione di autodiagnosi; protettore di guasti di fase in sequenza, protezione da sovraccarico del frigorifero; pressostato ad alta tensione, relè di sovraccarico, dispositivo di protezione termica e altre funzioni di protezione di sicurezza.
Refrigerante R-404A/R507C
L'interfaccia dell'antigelo è riservata all'interno della camera ZG3/4 e valvola di commutazione
Raffreddamento dell'acqua W I modelli con W sono raffreddati ad acqua
Condensatore raffreddato ad acqua Scambiatore di calore dell'involucro
Acqua di raffreddamento 32℃ 6m³/H
Materiale della scocca Spruzzatura di lastre laminate a freddo (colore standard 7035)

Inviaci un messaggio riguardo alla camera di prova per batterie
Inviaci un messaggio riguardo alla camera di prova per batterie
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

consigliare i prodotti

caricamento...

已经是到最后一篇内容了!

]]>
https://it.lneya.com/special-chiller/cooling-heating-temperature-control-flow-system/battery-test-chamber.html/feed 0
FLT-100℃~80℃ a bassa temperatura in cascata https://it.lneya.com/special-chiller/component-test-temp-control-systems/cooling-chiller-flt/flt-low-temperature-cascade-chiller.html https://it.lneya.com/special-chiller/component-test-temp-control-systems/cooling-chiller-flt/flt-low-temperature-cascade-chiller.html#respond Fri, 23 Feb 2024 06:25:34 +0000 https://www.lneya.com/?p=6966
FLT-100℃~80℃ a bassa temperatura in cascata

FLT -100℃~80℃

L'applicazione principale è il controllo accurato della temperatura nel processo di produzione dei semiconduttori e nel processo di test. Il metodo di riscaldamento è entro i 40°C e utilizza il gas caldo del compressore per riscaldare il concentrato.
  • Precisione della temperatura±0.1℃
  • Controllo del flusso12~45/min
  • TipoCascata a bassa temperatura
  • Gamma di potenza380V

Download dei dati del prodotto

Dettagli sulla configurazione

Modello

FLT-803W

FLT-805W

FLT-806W

FLT-808W

FLT-810W

Intervallo di temperatura

-80℃~+80℃

Precisione del controllo della temperatura

±0.1℃  

Controllo del flusso

7~25L/min

12~45L/min

 

Il controllo del flusso è regolato da un convertitore di frequenza e la velocità viene regolata automaticamente in base al segnale di feedback del sensore di flusso. La pressione massima del circolatore è di 6 bar.

Capacità di raffreddamento@-70℃

0,6KW

1KW

1,5KW

2KW

3KW

Potenza di riscaldamento

2KW

2KW

2KW

3,5KW

3,5KW

Volume del fluido di circolazione interno

4L

5L

6L

8L

10L

Volume del vaso di espansione

10L

10L

15L

15L

20L

Mezzo termico

Liquido fluorurato

Interfaccia di ingresso e di uscita

ZG1/2

ZG1/2

ZG3/4

ZG3/4

ZG3/4

Interfaccia acqua di raffreddamento

ZG3/4

ZG3/4

ZG3/4

G1

G1

Acqua di raffreddamento @20℃

1,8m3/h

2,5m3/h

3m3/h

5m3/h

6m3/h

Alimentazione

380V 50HZ

Rompighiaccio

25A

25A

32A

40A

50A

Modello

FLT-1002W

FLT-1004W

Intervallo di temperatura

-100℃~+80℃

-100℃~+80℃

Precisione della temperatura

±0.1℃  

±0.1℃  

Controllo del flusso 

7~25L/min

12~45L/min

 

Il controllo del flusso è regolato da un convertitore di frequenza e la velocità viene regolata automaticamente in base al segnale di feedback del sensore di flusso. La pressione massima del circolatore è di 6 bar.

Capacità di raffreddamento@-90℃

1,5KW

3KW

Potenza di riscaldamento

3,5KW

5,5KW

Volume del fluido di circolazione interno

5L

8L

Volume del vaso di espansione

10L

15L

Mezzo termico

Liquido fluorurato

Interfaccia di ingresso e di uscita

G3/4

G3/4

Interfaccia acqua di raffreddamento

G3/4

G1

Acqua di raffreddamento @20℃

50L/min 2bar~7bar

100L/min 2bar~7bar

Potenza

380V 50HZ

380V 50HZ

Rompighiaccio

32A

63A

Peso

700*800*1850

800*1200*1850

Applicazioni

Fare clic sul messaggio online per richiedere i dettagli del prodotto
Inviaci un messaggio riguardo al refrigeratore FLT
Inviaci un messaggio riguardo al refrigeratore FLT
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

consigliare i prodotti

caricamento...

已经是到最后一篇内容了!

]]>
https://it.lneya.com/special-chiller/component-test-temp-control-systems/cooling-chiller-flt/flt-low-temperature-cascade-chiller.html/feed 0
FLTZ -30℃~40℃ Serie a doppia conversione di frequenza https://it.lneya.com/special-chiller/component-test-temp-control-systems/cooling-chiller-flt/fltz-chiller-double-frequency-conversion.html https://it.lneya.com/special-chiller/component-test-temp-control-systems/cooling-chiller-flt/fltz-chiller-double-frequency-conversion.html#respond Fri, 23 Feb 2024 05:33:09 +0000 https://www.lneya.com/?p=6963
FLTZ -30℃~40℃ Serie a doppia conversione di frequenza

FLT Z -30℃~-40℃

Serie a doppia conversione di frequenza; Le pompe di circolazione e i compressori adottano la regolazione a conversione di frequenza.
  • Precisione della temperatura±0.1℃
  • Controllo del flusso15~45/min 6bar max
  • Pressione della pompa6Bar max
  • Gamma di potenza380V 3,5kW Riscaldamento

Download dei dati del prodotto

Dettagli sulla configurazione

Modello

FLTZ-305W

FLTZ-305W/2T Sistema doppio

Intervallo di temperatura

-30℃~40℃

-30℃~40℃

-30℃~40℃

Precisione del controllo della temperatura

±0.1℃  

±0.1℃  

±0.1℃  

Controllo del flusso 

15~45L/min ±0,3

15~45L/min ±0,3

15~45L/min ±0,3

Pressione della pompa

6 bar max

6 bar max

6 bar max

Riscaldamento

2,5kw

2,5kw

2,5kw

Capacità di raffreddamento@15℃

11kw

11kw

11kw

Capacità di raffreddamento@-15℃

5kw 约4500 giri/min.

5kw 约4500 giri/min.

5kw 约4500 giri/min.

Volume del fluido di circolazione interno

8L

8L

8L

Volume del vaso di espansione

15L

25L

Mezzo termico

Fluido fluorurato, antigelo, olio di silicone termico, ecc.

Interfaccia del mezzo termico

ZG3/4

ZG3/4

ZG3/4

Interfaccia acqua di raffreddamento

ZG3/4

ZG3/4

Acqua di raffreddamento

30L/min @20℃

60L/min @20℃

Potenza

220V 50/60HZ

220V 50/60HZ

Rompighiaccio

40A

80A

Peso

450*700*1600

650*850*1600

 

Riscaldamento elettrico opzionale da 3,5kw, la temperatura può essere estesa a 90℃, l'alimentazione deve essere cambiata a 380V.

Applicazioni

Fare clic sul messaggio online per richiedere i dettagli del prodotto
Inviaci un messaggio riguardo ai refrigeratori della serie FLTZ
Inviaci un messaggio riguardo ai refrigeratori della serie FLTZ
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

consigliare i prodotti

caricamento...

已经是到最后一篇内容了!

]]>
https://it.lneya.com/special-chiller/component-test-temp-control-systems/cooling-chiller-flt/fltz-chiller-double-frequency-conversion.html/feed 0
FLT -45℃~40℃ https://it.lneya.com/special-chiller/component-test-temp-control-systems/cooling-chiller-flt/flt-45-chiller.html https://it.lneya.com/special-chiller/component-test-temp-control-systems/cooling-chiller-flt/flt-45-chiller.html#respond Fri, 23 Feb 2024 05:07:30 +0000 https://www.lneya.com/?p=6954
FLT -45℃~40℃

FLT -45℃~40℃

Fluido fluorurato per raffreddamento e riscaldamento chiller
  • Precisione della temperatura±0.1℃
  • Controllo del flusso25~75/min 6bar max
  • RefrigentR404A
  • Gamma di potenza380V 3kW~15kW

Download dei dati del prodotto

Dettagli sulla configurazione

Modello

FLT-402

FLT-402W

FLT-403

FLT-403W

FLT-404

FLT-404W

FLT-406

FLT-406W

FLT-408

FLT-408W

FLT-410

FLT-410W

FLT-415

FLT-415W

Controllo della temperatura

 -45℃~40℃

Precisione del controllo della temperatura

±0.1℃  

Controllo del flusso  

10~25L/min 5bar max

15~45L/min 6bar max

25~75L/min 6bar max

Riscaldamento

Il riscaldamento del compressore viene utilizzato per prevenire la tecnologia di congelamento del condensatore.

Capacità di refrigerazione

@-35℃

1kw

1,4kw

1,8kw

2,5kw

3,3kw

5kw

8kw

Volume del fluido di circolazione interno

4L

5L

6L

8L

10L

12L

20L

Volume del vaso di espansione

10L

10L

15L

15L

20L

25L

35L

Refrigerante

R404A

Refrigerante secondario

Acqua, olio di silicone, liquido fluorurato, soluzione acquosa di glicole etilenico, ecc.

Interfaccia di ingresso e di uscita

G1/2

G1/2

G3/4

G3/4

G3/4

G1

G3/4

Collegamento all'acqua di raffreddamento

G1/2

G3/4

G3/4

G1

G1

G1

G1 1/8

Flusso di acqua di raffreddamento @20℃

1,5m³/H

2,4 m³/H

3,5 m³/H

5m³/H

5,5 m³/H

6m³/H

8m³/H

Potenza 380V

3KW

4KW

6KW

7,5KW

9KW

12KW

15KW

Espansione della temperatura

Aggiungendo un riscaldatore elettrico, la temperatura può essere estesa a -25℃~80℃.

Applicazioni

Fare clic sul messaggio online per richiedere i dettagli del prodotto
Inviaci un messaggio sui refrigeratori della serie FLT
Inviaci un messaggio sui refrigeratori della serie FLT
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

consigliare i prodotti

caricamento...

已经是到最后一篇内容了!

]]>
https://it.lneya.com/special-chiller/component-test-temp-control-systems/cooling-chiller-flt/flt-45-chiller.html/feed 0
FLT -25℃~40℃ https://it.lneya.com/special-chiller/component-test-temp-control-systems/flt-25-chiller.html https://it.lneya.com/special-chiller/component-test-temp-control-systems/flt-25-chiller.html#respond Fri, 23 Feb 2024 03:56:00 +0000 https://www.lneya.com/?p=6951
FLT -25℃~40℃

FLT -25℃~-40℃

Utilizzato principalmente per il controllo preciso della temperatura nei processi di produzione e collaudo dei semiconduttori, riscaldando entro i 40°C con il metodo di riscaldamento a gas caldo del compressore.
  • Precisione della temperatura±0.1℃
  • Controllo del flusso25~75/min 6bar max
  • RefrigentR404A
  • Gamma di potenza380V 3kW~17kW

Download dei dati del prodotto

Il metodo di riscaldamento entro 40 ℃ adotta un compressore per il riscaldamento a gas caldo completamente chiuso e la macchina funziona ininterrottamente per 24 ore.

Dettagli sulla configurazione

Modello

FLT-202

FLT-202W

FLT-203

FLT-203W

FLT-204

FLT-204W

FLT-206

FLT-206W

FLT-208

FLT-208W

FLT-210

FLT-210W

FLT-215

FLT-215W

Intervallo di temperatura

-25℃~40℃

Precisione del controllo della temperatura

±0.1℃  

Controllo del flusso  

10~25L/min ±0,3

15~45L/min ±0,3

25~75L/min ±0,3

Il controllo del flusso è regolato da un convertitore di frequenza e la pressione massima della pompa di circolazione è di 5 bar.

Refrigerazione

@-15℃

2kw

3kw

3,8kw

6kw

7,6kw

10kw

15kw

Circolazione interna Volume del fluido

4L

5L

6L

8L

10L

12L

20L

Volume del vaso di espansione

10L

10L

15L

15L

20L

25L

35L

refrigerante

R404A

Refrigerante secondario

Acqua, olio di silicone, liquido fluorurato, soluzione acquosa di glicole etilenico, ecc.

Interfaccia di ingresso e di uscita

G1/2

G1/2

G3/4

G3/4

G3/4

G1

G1

Collegamento all'acqua di raffreddamento

G1/2

G1/2

G3/4

G3/4

G1

G1

G1 1/8

Flusso d'acqua di raffreddamento@20℃

1,2 m³/H

1,6 m³/H

2,6 m³/H

3,6 m³/H

5,5 m³/H

7m³/H

10,2 m³/H

Potenza 380V

3KW

4KW

6KW

8KW

9KW

13KW

17KW

Espansione della temperatura

Aggiungendo un riscaldatore elettrico, la temperatura può essere estesa a -25℃~80℃.

 

Descrizione del prodotto

Il dispositivo di controllo della temperatura dei semiconduttori Chiller è utilizzato principalmente per il controllo preciso della temperatura nei processi di produzione e test dei semiconduttori. I suoi prodotti comprendono il controllo della temperatura del liquido fluorurato (minimo -100 gradi), il cambio rapido di temperatura del gas di raffreddamento e riscaldamento, il mandrino a cambio rapido di temperatura, la macchina di refrigerazione del gas a bassa temperatura (-120 gradi), l'unità di refrigerazione a raffreddamento diretto (-150 gradi), ecc. L'azienda applica vari algoritmi (PID, PID feedforward e algoritmo ad albero autocostruito model free) nel sistema per ottenere una risposta rapida e un'elevata precisione di controllo.

Applicazioni

Fare clic sul messaggio online per richiedere i dettagli del prodotto
Inviaci un messaggio sui refrigeratori della serie FLT
Inviaci un messaggio sui refrigeratori della serie FLT
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

consigliare i prodotti

caricamento...

已经是到最后一篇内容了!

]]>
https://it.lneya.com/special-chiller/component-test-temp-control-systems/flt-25-chiller.html/feed 0
Refrigeratore a scambio termico ETCU https://it.lneya.com/special-chiller/component-test-temp-control-systems/cooling-chiller-flt/heat-exchange-chiller-etcu.html https://it.lneya.com/special-chiller/component-test-temp-control-systems/cooling-chiller-flt/heat-exchange-chiller-etcu.html#respond Fri, 23 Feb 2024 03:28:34 +0000 https://www.lneya.com/?p=6948
Refrigeratore a scambio termico ETCU

FLT 5℃~-40℃

Controllo della temperatura dei semiconduttori

L'applicazione principale è il controllo accurato della temperatura nel processo di produzione dei semiconduttori e nel processo di test.

Il metodo di riscaldamento è entro i 40°C e utilizza il gas caldo del compressore per riscaldare il concentrato.

Il sistema di circolazione adotta un design completamente sigillato e la pompa di circolazione adotta una pompa a trascinamento magnetico.

Test dell'ammoniaca e test di sicurezza per garantire la sicurezza, l'affidabilità e la prosperità del sistema;

Dopo 24 ore di funzionamento continuo della copiatrice

Download dei dati del prodotto

Il metodo di riscaldamento entro 40 ℃ adotta un compressore per il riscaldamento a gas caldo completamente chiuso e la macchina funziona ininterrottamente per 24 ore.

Dettagli sulla configurazione

Modello

ETCU-005W

ETCU-008W

ETCU-015W

ETCU-030W

Intervallo di temperatura

Temperatura dell'acqua di raffreddamento +5℃~90℃ ±0,3℃

Temperatura dell'acqua di raffreddamento

7℃~30℃ Utilizzare la valvola di regolazione Siemens/Honeywell per controllare il flusso dell'acqua di raffreddamento

Capacità di raffreddamento

5kw

8kw

15kw

30kw

 

Condizioni di prova: Al massimo volume di circolazione, la differenza di temperatura tra la temperatura di controllo della temperatura e la temperatura dell'acqua di raffreddamento è di 15°C.

Flusso della pompa di circolazione

7~20L/min 5bar

7~20L/min 5bar

15~40L/min 5bar

20~60L/min 5bar

Volume del serbatoio

6L

8L

10L

15L

Dimensione

480*750*390

480*750*390

480*750*390

480*750*500

Potenza

220V 50HZ/60hz 0,6kw

220V 50HZ/60hz1.3kw

220V 50HZ/60hz 1.6kw

Descrizione del prodotto

Il dispositivo di controllo della temperatura dei semiconduttori Chiller è utilizzato principalmente per il controllo preciso della temperatura nei processi di produzione e test dei semiconduttori. I suoi prodotti comprendono il controllo della temperatura del liquido fluorurato (minimo -100 gradi), il cambio rapido di temperatura del gas di raffreddamento e riscaldamento, il mandrino a cambio rapido di temperatura, la macchina di refrigerazione del gas a bassa temperatura (-120 gradi), l'unità di refrigerazione a raffreddamento diretto (-150 gradi), ecc. L'azienda applica vari algoritmi (PID, PID feedforward e algoritmo ad albero autocostruito model free) nel sistema per ottenere una risposta rapida e un'elevata precisione di controllo.

Applicazioni

Fare clic sul messaggio online per richiedere i dettagli del prodotto
Inviaci un messaggio sui refrigeratori della serie FLT
Inviaci un messaggio sui refrigeratori della serie FLT
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

consigliare i prodotti

caricamento...

已经是到最后一篇内容了!

]]>
https://it.lneya.com/special-chiller/component-test-temp-control-systems/cooling-chiller-flt/heat-exchange-chiller-etcu.html/feed 0
FLT 5℃~-40℃ https://it.lneya.com/special-chiller/component-test-temp-control-systems/cooling-chiller-flt/flt-chillers.html https://it.lneya.com/special-chiller/component-test-temp-control-systems/cooling-chiller-flt/flt-chillers.html#respond Thu, 22 Feb 2024 06:38:27 +0000 https://www.lneya.com/?p=6825
FLT 5℃~-40℃

FLT 5℃~-40℃

Utilizzato principalmente per il controllo preciso della temperatura nei processi di produzione e collaudo dei semiconduttori, riscaldando entro i 40°C con il metodo di riscaldamento a gas caldo del compressore.
  • Precisione della temperatura±0.1℃
  • Controllo del flusso25~75/min 6bar max
  • RefrigentR404A
  • Gamma di potenza380V 3,5kW~16kW

Download dei dati del prodotto

Il metodo di riscaldamento entro 40 ℃ adotta un compressore per il riscaldamento a gas caldo completamente chiuso e la macchina funziona ininterrottamente per 24 ore.

Dettagli sulla configurazione

Modello

FLT-002

FLT-002W

FLT-003

FLT-003W

FLT-004

FLT-004W

FLT-006

FLT-006W

FLT-008

FLT-008W

FLT-010

FLT-010W

FLT-015

FLT-015W

Controllo della temperatura

 5℃~40℃

Precisione della temperatura

±0.1℃  

Controllo del flusso  

10~25L/min 5bar max

15~45L/min 6bar max

25~75L/min 6bar max

Capacità di refrigerazione@10℃

 6kw

 8kw

 10kw

15 kw

 20kw

 25kw

 40kw

Volume del liquido di circolazione interno

4L

5L

6L

8L

10L

12L

20L

Capacità del vaso di espansione

10L

10L

15L

15L

20L

25L

35L

Refrigerante

R410A

Refrigerante secondario

Olio di silicone, liquido fluorurato, soluzione acquosa di glicole etilenico, DI, ecc. (la temperatura di DI deve essere controllata al di sopra di 10 ℃).

Interfacce di ingresso e di uscita

G1/2

G1/2

G3/4

G3/4

G3/4

G1

G1

Uscita acqua di raffreddamento

G1/2

G1/2

G3/4

G1

G1

G1

G1 1/8

Portata dell'acqua di raffreddamento@20℃

1,5 m³/h

2m³/h

2,5 m³/h

4m³/h

4,5 m³/h

5,6 m³/h

9m³/h

alimentazione 380V

3,5kW

4kW

5,5kW

7kW

9,5kW

12kW

16kW

Estensione della temperatura

Aggiungendo un riscaldatore elettrico, è possibile ampliare l'intervallo di temperatura da -25 ℃ a 80 ℃.

Descrizione del prodotto

Il dispositivo di controllo della temperatura dei semiconduttori Chiller è utilizzato principalmente per il controllo preciso della temperatura nei processi di produzione e test dei semiconduttori. I suoi prodotti comprendono il controllo della temperatura del liquido fluorurato (minimo -100 gradi), il cambio rapido di temperatura del gas di raffreddamento e riscaldamento, il mandrino a cambio rapido di temperatura, la macchina di refrigerazione del gas a bassa temperatura (-120 gradi), l'unità di refrigerazione a raffreddamento diretto (-150 gradi), ecc. L'azienda applica vari algoritmi (PID, PID feedforward e algoritmo ad albero autocostruito model free) nel sistema per ottenere una risposta rapida e un'elevata precisione di controllo.

Applicazioni

Fare clic sul messaggio online per richiedere i dettagli del prodotto
Inviaci un messaggio sui refrigeratori della serie FLT
Inviaci un messaggio sui refrigeratori della serie FLT
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

consigliare i prodotti

caricamento...

已经是到最后一篇内容了!

]]>
https://it.lneya.com/special-chiller/component-test-temp-control-systems/cooling-chiller-flt/flt-chillers.html/feed 0
ZLJ -40℃~-15℃ https://it.lneya.com/industrial-chiller/direct-cooling-zlj-40-15.html https://it.lneya.com/industrial-chiller/direct-cooling-zlj-40-15.html#respond Thu, 06 Jul 2023 03:10:47 +0000 https://www.lneya.com/?p=6798
ZLJ -40℃~-15℃

ZLJ -40℃~-15℃

Refrigeratore raffreddato ad aria per il processo di produzione dei semiconduttori
  • Compressore1,5 CV~7 CV
  • RefrigentR404A R507C R448
  • Gamma di potenza380V 50HZ può scegliere 220V
  • Precisione della temperatura±0.5℃

Download dei dati del prodotto

Tipo di raffreddamento diretto del refrigeratore

I requisiti di controllo multipli possono essere raggiunti unendo più dispositivi in un armadio più grande.

Dettagli sulla configurazione

Modello ZLJ-41.0 ZLJ-41.5 ZLJ-42 ZLJ-43 ZLJ-44 ZLJ-46 ZLJ-48
ZLJ-41.0W ZLJ-41.5W ZLJ-42W ZLJ-43W ZLJ-44W ZLJ-46W ZLJ-48W
Intervallo di temperatura  -40℃~-10℃
Precisione del controllo della temperatura Temperatura di evaporazione di controllo ±0,5
Metodo di strozzatura Valvola di espansione elettronica
Controllore PLC Siemens
Mostra il record Schermo touch screen da 7 pollici, registrazione della temperatura, della pressione del sistema e di altre informazioni
Componenti principali Filtro disidratatore Danfoss, elettrovalvola Castor, sensore di pressione Johnson Controls, ventola EBM (raffreddata ad aria), separatore d'olio Danfoss/Emerson,
Compressore Secop, Taikang, Emerson, Carlisle
Refrigerante R404A Opzionale R507C R448
Raffreddamento ad alta temperatura Con la tecnologia di raffreddamento diretto ad alta temperatura a 150 gradi, per raggiungere l'obiettivo di una rapida capacità di raffreddamento durante il funzionamento ad alta temperatura.
Compressore 7/8HP 1,5HP 2HP 3HP 4HP 6HP 8HP
Alimentazione V 220V 50HZ 380V 50HZ Può essere personalizzato 220V

Descrizione del prodotto

Il prodotto emette ed evapora direttamente il refrigerante nel sistema di refrigerazione nell'elemento di controllo target (scambiatore di calore) per lo scambio di calore, raffreddando così l'oggetto di controllo target. Rispetto al fluido (gas) trasportato nello scambiatore di calore, la capacità di scambio termico è generalmente più di 5 volte superiore, il che è particolarmente adatto per applicazioni in cui l'area di scambio termico dello scambiatore di calore è piccola ma la capacità di scambio termico è grande.

Il frigorifero a raffreddamento diretto può essere utilizzato anche come cattura di gas; il refrigerante viene fatto passare direttamente nella trappola per evaporare e il gas presente nello spazio viene rapidamente catturato grazie all'effetto di condensazione sulla superficie della trappola.

Fare clic sul messaggio online per richiedere i dettagli del prodotto
Inviaci un messaggio su Refrigeratore a raffreddamento diretto
Inviaci un messaggio su Refrigeratore a raffreddamento diretto
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

consigliare i prodotti

caricamento...

已经是到最后一篇内容了!

]]>
https://it.lneya.com/industrial-chiller/direct-cooling-zlj-40-15.html/feed 0