Ricerca nell'intera stazione


blog

Sulla selezione dei prodotti LNEYA, i vantaggi e le informazioni sull’industria dei chiller.

SUNDI -100℃~135℃
SUNDI -100℃~135℃
SUNDI -100℃~135℃
SUNDI -100℃~135℃
SUNDI -100℃~135℃

SUNDI -100℃~135℃

Controllo della temperatura del reattore e del materiale
  • Potenza di riscaldamento3,5kW~80kW
  • Capacità di raffreddamento0,45kW~80kW
  • Gamma di potenza12kW~200kW
  • Accuratezza media±0.5℃~±1℃
  • Precisione del materiale±1℃
  • RefrigeranteR404A/R23/R14
  • Peso435KG~3350KG

<trp-post-container data-trp-post-id='5159'>SUNDI -100℃~100℃</trp-post-container> - reactor heating cooling(images 6)

● Working temperatures from -120°C to +350°C
● Previously unachievable performance
●Intelligent temperature control
● Maximum process stability and reproducibility
● Adop plate heat exchager, Pipeline heating, the fastest heating and cooling rates.
● High cooling power from 0.5 to 1200kW
● Large temperature range without fluid change
● Closed system, extend thermal fluid lifetime
● 7-inch, 10-inch color TFT touch screen display
● Comprehensive warning and safety functions
● Rapid cooling down from high temperature (from 300 °C)
● Use magnetic drive pump, solve the circulation pump leakage

Dettagli sulla configurazione

SUNDI- 1035W 1055W 1075W 10A10W 10A15W 10A25W 10A38W 10A60W 10A80W
Intervallo di temperatura -100℃~+135℃(the system add pressure 3bar)
Modalità di controllo Feedback PID + il nostro speciale calcolo di controllo dinamico, controllore PLC
Controllo della temperatura Modello di controllo della temperatura di processo e del rivestimento
Differenza di temperatura Impostare o controllare la differenza di temperatura tra l'olio del rivestimento e la materia prima.
Editor del programma 10 programmi, ogni programma può modificare 40 passi.
Portocollo di comunicazione Protocollo MODBUS RTU, interfaccia RS485
Feedback sulla temperatura del materiale PT100 OR 4~20mA or communication(normal: PT100)
Feedback temp. La temperatura di tre punti: ingresso e uscita dell'apparecchiatura, temperatura del materiale del reattore (sensore di temperatura esterno).
Precisione a media temperatura ±0.5℃
Precisione della temperatura del materiale ±1℃
Potenza di riscaldamento kW 3.5 5.5 7.5 10 15 25 38 60 80
Capacità di raffreddamento kW a 135℃ 3.5 5.5 7.5 10 15 25 38 60 80
0℃ 3.5 5.5 7.5 10 15 25 38 60 80
-60℃ 2.8 5 6.2 8 9 15 23 38 52
-80℃ 1.9 2.8 3.4 4.1 5 8 13 22 30
-90℃ 0.7 1.2 1.6 2 3 4.8 7.5 12 16
-100℃ 0.45 0.7 0.9 1.2 1.8 2.9 4.5 7.2 9.5
Pompa di circolazione max
L/min bar
35 35 50 60 110 150 200 400 400
12 1.2 1.2 1.5 1.5 1.5 1.5 2.5 2.5
Pompa Pompa a trascinamento magnetico
Compressore Compressore Dorin semichiuso
Separatore d'olio EMERSON
Valvola di espansione Valvola di espansione elettronica
Evaporatore Scambiatore di calore a piastre
Pannello operativo 7-inch touch screen,show temp curve\EXCEL data output
Protezione di sicurezza Funzione di autodiagnosi; protezione da sovraccarico del congelatore; pressostato di alta pressione, relè di sovraccarico, dispositivo di protezione termica, protezione da basso livello del liquido, protezione da alta temperatura e protezione da guasto della temperatura.
Sistema di circolazione chiuso L'intero sistema è a circolazione completamente chiusa, non c'è nebbia d'olio ad alta temperatura e non c'è vapore acqueo a bassa temperatura, la pressione non sale quando il sistema è in funzione. Il sistema fornisce automaticamente olio a bassa temperatura.
Refrigerante R404A/R23/R14
Dimensioni del collegamento ZG3/4 ZG3/4 ZG1 ZG1 DN32 PN10 DN32 PN10 DN40 PN10 DN65 PN10 DN65 PN10
Water-cooled type W(cooling water@20℃) 3500L/H
1,5bar~4bar
5000L/H
1,5bar~4bar
7000L/H
1,5bar~4bar
9000L/H
1,5bar~4bar
12m³/H
1,5bar~4bar
20m³/H
1,5bar~4bar
25m³/H
1,5bar~4bar
40m³/H
1,5bar~4bar
50m³/H
1,5bar~4bar
Dimensioni(cm) 80*120*185 80*120*185 150*100*185 150*100*185 200*145*205 205*145*205 250*160*225 300*160*225 400*160*225
Peso kg 435 565 705 890 1250 1600 2100 2950 3350
Potenza 380V 50HZ 12kW max 18kW max 24kW max 30kW max 40kW max 60kW max 85kW max 135kW max 200kW max

Principio di funzionamento

<trp-post-container data-trp-post-id='5159'>SUNDI -100℃~100℃</trp-post-container> - sundi(images 7)
<trp-post-container data-trp-post-id='5159'>SUNDI -100℃~100℃</trp-post-container> - thermostat(images 8)

<trp-post-container data-trp-post-id='5159'>SUNDI -100℃~100℃</trp-post-container> - dynamic temperature control system(images 9)

Applicazioni: Vari reattori (microcanali, vetro, reattori con rivestimento, ecc.), sistema di distillazione o estrazione, laboratorio, università, istituto di ricerca, industria aerospaziale, automobilistica, test di semiconduttori ed elettrici, chimica, farmaceutica, petrolchimica, biochimica, medica, ospedaliera, officina di ricerca e sviluppo, aerospaziale, biologica e altre industrie.

Inviaci un messaggio sul prodotto
*
*
正在提交中….
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

Potreste essere interessati anche a questi prodotti

  • Serie ZLT HED"      /&gt;<figcaption><span>Questo dispositivo può introdurre direttamente i mezzi chimici e controllare con precisione la temperatura, fungendo da preriscaldamento, pre-raffreddamento e controllo della temperatura del mezzo prima della reazione chimica. I mezzi chimici includono l'a...</span></figcaption></figure></a></div><div class= Serie ZLT HED

    Questo dispositivo può introdurre direttamente i mezzi chimici e controllare con precisione la temperatura, fungendo da preriscaldamento, pre-raffreddamento e controllo della temperatura del mezzo prima della reazione chimica. I mezzi chimici includono l'a...

  • Serie di convertitori di frequenza SUNDI Z"      /&gt;<figcaption><span>WHATSAPP WECHAT La tecnologia di raffreddamento ad altissima temperatura può raffreddare direttamente da una temperatura elevata di 300℃[perché solo il mezzo di trasferimento di calore nell'espansione...</span></figcaption></figure></a></div><div class= Serie di convertitori di frequenza SUNDI Z

    WHATSAPP WECHAT Ultra high temperature cooling technology can directly cool from a high temperature of 300℃[because only the heat transfer medium in the expansion…

  • SUNDI -10℃~150℃"      /&gt;<figcaption><span>Sistema completamente chiuso, singolo mezzo completa la refrigerazione e il riscaldamento -120~350℃ ±0,5℃ AC 380V 50HZ 8kW max La tecnologia di raffreddamento ad altissima temperatura può...</span></figcaption></figure></a></div><div class= SUNDI -10℃~150℃

    Fully enclosed system, single medium completes refrigeration and heating -120~350℃ ±0.5℃ AC 380V 50HZ 8kW max Ultra high temperature cooling technology can directly cool from a hi…

  • SUNDI -45℃~300℃"      /&gt;<figcaption><span>● Temperature di lavoro da -120°C a +350°C ● Prestazioni finora irraggiungibili ● Controllo intelligente della temperatura ● Massima stabilità e riproducibilità del processo ● Scambiatore di calore a piastre Adop, riscaldamento a...</span></figcaption></figure></a></div><div class= SUNDI -45℃~300℃

    ● Working temperatures from -120°C to +350°C ● Previously unachievable performance ●Intelligent temperature control ● Maximum process stability and reproducibility ● Adop plate heat exchager, Pipeline heating, the fastes…

loading…

已经是到最后一篇内容了!

Espandere di più!