Used in pharmaceutical factories, hospitals, laboratories and other places with high cleanliness requirements and high precision temperature and humidity requirements.

| Modello | LMW-01BS | LMWX-01BS | LMW-03BT | LMWX-03BT | |
| Rated Airflow | m3/min | 0.7~1.0 | 2.0~4.0 | ||
| Gamma di temperatura e umidità regolabile | ℃/ %RH | 21~26 | 21~26;45%RH~60%RH | 21~26 | 21~26;45%RH~60%RH |
| Precisione del controllo di temperatura/umidità | ℃/ %RH | ±0.1 | ±0.1;±1.0%RH | ±0.1 | ±0.1;±1.0%RH |
| Maximum Cooling Capacity(50/60Hz) | KW | 0.2/0.25 | 0.37/0.45 | 1.3 | 1.3 |
| Reheating Capacity(50/60Hz) | KW | 0.1/0.13 | 0.4 | 0.5 | 0.7 |
| Maximum Humidification Capacity | Kg/h | / | 0.8 | / | 2.3 |
| Humidification Water Supply Temperature Range | ℃ | / | 10~40 | / | 10~40 |
| Humidification Makeup Water Pipe Connection | / | / | Rc1/2 | / | Rc1/2 |
| Humidification Makeup Water Pressure | bar | / | 0.3~2 | / | 0.3~2 |
| Water Quality Requirement | / | / |
*Conductivity125~1250μs/cm *Water hardness not exceeding 40°f *Free of organic compounds |
/ |
*Conductivity 125~1250μs/cm *Water hardness not exceeding 40°f *Free of organic compounds |
| Maximum External Static Pressure of Supply Air | Pa | 120/130 | 120/160 | 110/150 | 110/150 |
| Supply Air Outlet Connection Diameter | mm | φ75 | φ100 | φ100 | φ100 |
| Equipment Ambient Temperature | ℃/ %RH | 20~26;40%RH~60%RH ① | |||
| Ambient Temperature Accuracy Range | ℃/ %RH | ±1;±5%RH | |||
| Alimentazione | V/Hz | 1~220v±10%; 50/60Hz±5Hz | 3~380v±15%; 50Hz±5Hz ④ | ||
| Unit Rated Input Power | KW | 0.32/0.34 | 1.2/1.2 | 0.75 ⑤ | 2.7 ⑤ |
| Max Operating Current of Unit | A | 1.7/1.82 | 6.4/6.4 | 1.35 | 4.8 |
| Unit Noise Level(50/60Hz) | dB(A) | 54/56 | 58/60 | 65 | 66 |
| Max Input Power of Unit | KWA | 0.34/0.38 | 1.5/1.5 | 1.4 | 4 |
| Refrigerant/Charge Quantity | Kg | R134A/0.13 | R407C/0.3 | R410A/0.4 | R410A/0.48 |
| Unit N.W | Kg | 32 | 69 | 95 | 135 |
| Unit G.W | Kg | 40 | 85 | 110 | 150 |
| Unit Overall Dimensions(L*B*H) | mm | 500*412*346 | 630*390*765 | 590*480*1070 | 680*520*1350 |
| Unit Packaging Dimensions (L*B*H) | mm | 600*500*400 | 750*500*850 | 700*600*1200 | 780*650*1400 |
| Product Model | LW-0090-BW01 | LWX-0090-BW01 | LW-0100-BW01 | LWX-0100-BW01 | |
| Rated Airflow | m3/h | 8000~9000 | 9000~10000 | ||
| Gamma di temperatura e umidità regolabile | ℃/ %RH | 22~23;45%RH | 22~23;45%RH | 22~23 | 22~23;45%RH~70%RH |
| Temp./Humidity Control Accuracy | ℃/ %RH | ±0.1 | ±0.1;±1%RH | ±0.1 | ±0.1;±1.0%RH |
| Max Cooling Capacity | KW | 20kw @25℃ | 16kw @26℃ | ||
| Max Humidification Capacity | Kg/h | / | 5 | / | 2.3 |
| Outdoor Air Ratio ② | 20% | 20% | / | / | |
| Equipment Outdoor Air Temp & Humidity Range | ℃/ %RH | 23±2;;40%~60%±2%RH | 25; 50%RH | ||
| Equipment Return Air Temp & Humidity Range | ℃/ %RH | 23±0.1;45%RH ±2%RH | / | ||
| Max External Static Pressure of Supply Air | Pa | 300~400 | 0~200 | ||
| Supply Air Outlet Connection Diameter | mm | φ500 | φ500 | ||
| Humidification Water Supply Temp Range | ℃ | / | 10~40 | / | 10~40 |
| Humidification Makeup Water Pipe Connection | / | / | Rc1/2 | / | Rc1/2 |
| Humidification Makeup Water Pressure | bar | / | 1~4 | / | 1~4 |
| Water Quality Requirement | / | / |
*Conductivity75~1250μs/cm *Water hardness not exceeding 40°f *Free of organic compounds |
/ |
*Conductivity 75~1250μs/cm *Water hardness not exceeding 40°f *Free of organic compounds |
| Cooling Water Temperature | ℃ | 18~22 | 18~22 | ||
| Cooling Water Connection | G1″ | G1″ | |||
| Alimentazione | V/Hz | 3~380v±10%; 50Hz±5Hz Three-phase five-wire system | |||
| Unit Rated Input Power | KW | 12.5 | 12.5 | 4 | 4 |
| Maximum Operating Current of Unit | A | 23 | 23 | 7 | 7 |
| Unit Noise Level | dB(A) | ≤80 | ≤75 | ||
| Maximum Input Power of Unit | KWA | 15 | 8 | ||
| Refrigerant/Charge Quantity | Kg | R410A/4 | R410A/4 | ||
| Safety Protection Functions | Power overvoltage and undervoltage protection; phase reversal and loss protection; motor overheat and overload protection; compressor discharge temperature overheat protection; system high pressure protection; system low pressure protection; temperature module fault protection; adjustable over-temperature protection; fan motor overheat protection, etc. | ||||
| Unit N.W | Kg | 750 | 800 | 650 | 680 |
| Unit G.W | Kg | 800 | 850 | 700 | 750 |
| Unit Overall Dimensions (L*B*H) | mm | 2130*1000*2000 | 1200*1200*1950 | ||
| Unit Packaging Dimensions(L*B*H) | mm | 2300*1150*2100 | 1350*1350*2050 | ||
The equipment, production processes, inspection processes and spaces used in production facilities for equipment such as semiconductors, liquid crystals and solar panels require highly accurate and stable air processing.


WeChat/Telefono
86 18914253067

+86 18914253067

Indirizzo e-mail
market@lneya.com
Tutti i modelli di chiller per semiconduttori

Capacità di raffreddamento 6kW~40kW
Portata dell'acqua di raffreddamento 1,5m³/h~9m³/h
Precisione della temperatura ±0.05℃

Capacità di raffreddamento 2kW~15kW
Portata dell'acqua di raffreddamento 1,2m³/h~10,2m³/h
Precisione della temperatura ±0.05℃

Capacità di raffreddamento 1kW~8kW
Portata dell'acqua di raffreddamento 1,5m³/h~8m³/h
Precisione della temperatura ±0.05℃

Capacità di raffreddamento 0,6kW~3kW
Portata dell'acqua di raffreddamento 1,8m³/h~6m³/h
Precisione della temperatura ±0.05℃

Capacità di raffreddamento 1,5kW~3kW
Portata dell'acqua di raffreddamento 50L/min~100L/min 2bar~7bar
Precisione della temperatura ±0.05℃
Refrigeratore industriale Fornitore in Cina
❯Oltre 15 anni di esperienza nella progettazione e produzione
❯Servizio completo
❯Tempi di consegna brevi
❯Solido servizio post-vendita e supporto tecnico
❯Controllo della temperatura altamente preciso e ripetibile
❯Prodotto a Wuxi, Cina
❯Oltre 130 brevetti


Abbiamo servito più di 30.000 clienti.
Esportato in oltre 20 paesi.

Ha ottenuto la certificazione CE, la certificazione SGS e la certificazione ISO.

Fornire una formazione tecnica completa.
Con soluzioni 24/7.

Fondata nel 2010, con 15 anni di esperienza nel settore.
Il 20% dei dipendenti sono tecnici.

Ispezione visiva
Test di prestazione.
Test di sicurezza elettrica.
Have a question or need a quote?
Fill out the form below, and our team will get back to you within 24 hours.