Quali sono le differenze tra camera di prova a bassa temperatura e refrigerazione?
Il low temperature test chamber, you can see by its name, probably means to do cryogenic test. It is more important in our refrigeration equipment. The small series of low temperature test chamber tells you that the refrigeration of low temperature test chamber under different refrigeration modes is also different. So what refrigeration modes are there? Let’s have a look together with the low temperature test box.
Differentiation of low temperature test chamber by Temperature Range
Different materials in different industries have different temperature requirements for the low temperature test chamber. If the temperature you need is below 100 degrees below zero, liquid nitrogen refrigeration is recommended. If the temperature is between 0 and 100 degrees, the low temperature test chamber for compressor refrigeration is selected. Because the cryogenic temperature required by the former is lower, it is more convenient to choose liquid nitrogen.
Separation of low temperature test chamber by refrigeration.
Generally speaking, refrigeration methods include compressor refrigeration and liquid nitrogen refrigeration. The small series of low temperature test chamber tells us that compressor refrigeration is to set refrigeration system and evaporator in the test chamber, and to set environmental protection refrigerant inside the evaporator through throttling device to evaporate inside the evaporator and absorb external heat, which is to cool the test box. If it is liquid nitrogen refrigeration, it is direct liquid nitrogen spraying inside the test box, making it endothermic vaporization, taking heat and cooling.
Differentiation of the low temperature test chamber by cooling rate.
The cooling rate of the low temperature test chamber under different refrigeration modes is fast and slow. The low temperature test chamber with liquid nitrogen refrigeration has a faster cooling rate. At this time, you need to consider the problem of constant temperature and overshoot. On the contrary, if the low temperature test chamber with compressor refrigeration is high in cost, the cooling rate is generally set to a constant value.
By sharing these, we must have a certain understanding of the refrigeration mode of the low temperature test chamber. When you do the cryogenic test, you must choose the cryogenic test box suitable for your temperature, refrigeration and cooling rate.
Raccomandazioni correlate
-
Accessori per sistemi di controllo della temperatura di refrigerazione dei semiconduttori
1683Nell'evaporatore, poiché il liquido evapora nell'evaporatore del sistema di controllo della temperatura di refrigerazione dei semiconduttori, il processo da liquido a gas, a causa del cambiamento del carico, parte del refrigerante potrebbe non essere completamente evaporato...
Visualizza dettagli -
Descrizione dei guasti comuni del gruppo frigorifero a semiconduttori LNEYA
2051Se si verifica un allarme di alta tensione nell'unità di refrigerazione dei semiconduttori, è necessario verificare se le tubazioni esterne sono bloccate o sporche. Pulire e rimuovere in tempo. Se si tratta di un dispositivo di refrigerazione a semiconduttori raffreddato ad aria, è necessario ...
Visualizza dettagli -
What is the reason for non condensable gas in the condenser of ultra-low temperature cooling water c
2273When the ultra-low temperature cooling water chiller is running, it is necessary to pay attention to the gas state generated by the condenser under a certain temperature and pressure. The existence of these gases affects the operation of the ultra...
Visualizza dettagli -
Dove servono i refrigeratori d'acqua antideflagranti?
1329Explosion-proof refrigeration unit water chillers (explosion-proof chillers) are mainly used in environments with explosion risks to ensure the safety and reliability of the cooling process. This type of equipment is specially designed to ...
Visualizza dettagli
Refrigeratori industriali LNEYA Produttore Fornitore