Sistema di controllo della temperatura di prova dell'antigelo per autoveicoli
When it comes to car antifreeze, we all know that its main function is to prevent the coolant from freezing and cracking the radiator and freezing the engine cylinder block or cover when we stop in the cold winter. Make the cooling system in the best working condition and ensure the normal working temperature of the engine.
The freezing point of water is 0°C, and ordinary antifreeze can reach -40°C, while high-quality antifreeze should be able to reach about -60°C, and the antifreeze has a high boiling point. The boiling point of water is 100 °C, and the boiling point of high-quality antifreeze coolant is usually 110 °C above zero, so it is more difficult to boil antifreeze coolant than water in summer.
Antifreeze detection items: freezing point detection, antifreeze detection, low temperature stability, thermal stability, etc. In these tests, temperature control is left off. When the testing organization carries out these testing items, it is necessary to ensure the constant temperature environment, cooling and heating temperature difference, time and so on during the testing process.
LNEYA automotive antifreeze cooling, heating, temperature control and flow system KRY series equipment is the temperature and flow control equipment required by this type of organization. The temperature range is minus 40 degrees to 100 degrees. The temperature changes during the test are visualized, and the data storage and report analysis can be exported for the convenience of the technicians of the testing organization.
The temperature test mentioned here is the high temperature endurance test and the low temperature endurance test. The low temperature endurance test mainly tests the cold start performance, the charging and discharging ability, the charging and discharging ability of the battery pack at high temperature, the cooling function of the battery pack and the overheat protection strategy.
Our LNEYA KRY series cooling, heating, temperature and flow control systems are the best choice for testing institutions, saving costs and increasing the efficiency and accuracy of testing.
Raccomandazioni correlate
-
Multi-stage refrigeration small temperature control compressor description
1664The function of the compressor in the multi-stage refrigeration small temperature control station system is to draw the refrigerant vapor of the evaporator and increase its temperature and pressure, which is discharged into the condenser. In the c...
Visualizza dettagli -
Low-temperature coolant circulation pump used with rotary evaporator
1895The chemical and pharmaceutical fields are the largest end consumer markets for cryogenic coolant circulation pumps. With the increasing demand for low-temperature coolant circulation pumps in this market, the application of cryogenic pumps in the...
Visualizza dettagli -
Refrigeratore per bollitore di distillazione da 200 l
1222Il refrigeratore per il bollitore di distillazione da 200 litri deve soddisfare due funzioni principali allo stesso tempo: una è quella di condensare il vapore di metanolo e l'altra è quella di raffreddare il materiale durante il processo di reazione. ...
Visualizza dettagli -
What are the main equipment needed for industrial chillers?
1341Main equipment of industrial chiller: compressor, condenser, expansion valve, evaporator, chilled water pump, cooling water pump cooling tower (water cooling) Selection: know the required inlet and outlet water temperature, the required cooling ca...
Visualizza dettagli
Refrigeratori industriali LNEYA Produttore Fornitore










