Risoluzione dei guasti più comuni dei refrigeratori d'acqua industriali
As we all know, with the rapid development of modern industrial technology, in order to improve production efficiency, improve product quality and reduce consumption costs, the demand for temperature control equipment in the process is higher and higher, but there are more and more product quality problems about some industrial water chillers, So we simply analyze some common problems about industrial water chillers.
Abnormal temperature at the inlet and outlet of cooling water: the water temperature at the inlet of condenser is too high (higher than 32 ℃), first check whether the fan of cooling tower can be reversed (there are such examples in practical engineering). Then, after technical demonstration and on the premise of feasibility, adjust the blade angle of the fan to improve the air volume of the fan.
Another phenomenon often occurs in the system with multiple cooling towers in parallel. When the local load is running, the temperature difference between the inlet and outlet of the condenser is too small. It is necessary to check whether each cooling tower has been equipped with an electric valve, or whether the set electric valve fails to form a cooling water bypass, which can not be cooled completely.
The differential pressure at the inlet and outlet of cooling water is abnormal. According to the relevant refrigeration theory, the heat release of the condenser will directly affect the refrigeration capacity. Therefore, the user should first check the cooling water system based on the pressure loss value on the main engine. If the pressure difference obtained from the value of the pressure gauge at the inlet and outlet greatly exceeds the normal value, it indicates that there are sundries at the inlet of the condenser.
Raccomandazioni correlate
-
I principali campi di applicazione dei refrigeratori raffreddati ad aria
1853Inthe domestic and international industrial water chiller market, our most commonindustrial water chiller equipment can be roughly divided into two differenttypes, one type is industrial air cooled chiller, the other type is industrialwater co...
Visualizza dettagli -
Chip di controllo del riscaldamento a bassa temperatura e altri metodi di rilevamento
1723Con la ricerca e lo sviluppo della tecnologia dei chip, anche la tecnologia di rilevamento dei chip sta maturando. La tecnologia dei chip di controllo del riscaldamento a bassa temperatura di LNEYA viene applicata al rilevamento dei chip. Oltre a questo tipo di tecnologia di rilevamento, ci sono altri...
Visualizza dettagli -
Suggerimenti per il rilevamento di perdite nel congelatore a bassa temperatura
1470Rilevamento delle perdite per immersioneLa sensibilità del rilevamento delle perdite per immersione è superiore a quella del test delle bolle, che viene solitamente applicato alle piccole unità freezer Freon. Quando si utilizza, l'apparecchiatura che non può entrare in contatto con l'acqua nel sistema deve essere...
Visualizza dettagli -
Refrigeratori industriali LNEYA Produttore Fornitore