Impact and Solution of Excess Exhaust Temperature of Industrial Chiller Units
Industrial water chiller compressor exhaust temperature determines whether the equipment can stably and efficiently run. The common problem of compressor is excess exhaust temperature. Once the situation appears, it is easy to make industrial chiller high pressure and high temperature, overload, reduced working efficiency and poor industrial water chiller compressor refrigerating capacity. It can also lead to other problems. So how to reduce the exhaust temperature of industrial water chillers and cool the compressor, we are the experts to develop water chiller refrigeration system 320/420 w / 430 w experts, so today LNEYA will recommend a few solutions for you:
Increase cooling water flow and heat ventilation of water tank and water tower:
Air-cooled water tank of industrial cold water machine and cooling water in industrial cooling towers are to cool the condenser and transfer heat which can take away the heat generated by the compressor work. If you can guarantee the cooling water flow rate and air cooling industry cold water machine water tanks, water chiller water tower cooling ventilation ability, you will keep cooling water temperature to within the limits defined, so as to maximize the cool the compressor.
Reduce the exhaust temperature of the refrigeration compressor directly:
You can start from decreasing compression ratio and the load of the compressor. Lower compression ratio will make compressor low efficient, but it can solve the problem of excess exhaust temperature of compressor.

Raccomandazioni correlate
-
LNEYA temperature control system AH series commentary
1102Refrigeration heating temperature control system AH series, suitable for high heat release, suitable for SUS reactor, temperature difference > 150 ° C, can quickly cool high temperature reaction, polymerization reaction and rapid heating and co...
Visualizza i dettagli -
Where do you need low temperature chiller and introduction
869Even though water is one of the most precious and scarce resources, it is still used as a coolant in many laboratories. Unfortunately, most of the water used as a coolant is not recycled, resulting in higher and higher laboratory costs and wasted ...
Visualizza i dettagli -
Configuration form of circulating heating unit for laboratory
909The standard model of the circulating heating unit for LNEYA laboratory is: SUNDI, the temperature range is from room temperature to minus 120 degrees Celsius, and the capacity can be divided into 5L, 10L, 20L, 30L, 40L, 50L, 80L, 100L, larger cap...
Visualizza i dettagli -
What are the applications of steam circulators in chemical industry?
956The steam circulator in the chemical industry is a temperature control equipment in the pharmaceutical and chemical industry. When users operate, they need to understand the performance and maintenance knowledge in order to operate the equipment e...
Visualizza i dettagli