Small temperature control system equipment welding maintenance precautions
Small thermostat control system equipment pay attention to the point of comparison when repairing, LNEYA professional manufacturers reminded that the welding part is also one of the key points of maintenance, then what aspects should be paid attention to when welding?
When the small-scale thermostat control system equipment is welded, protective measures should be taken for the chassis and various components to prevent the flame from being burned by the torch. When welding, pay attention to the adjustment of the torch flame. When the flame is adjusted to the neutral flame, it can be welded. The speed should be as fast as possible to avoid damage to the compressor, the refrigeration valve body and the copper pipe.

If the copper tube is black after soldering, it should be adjusted to increase the flux flow until the copper tube is purple after soldering. When replacing the plate heat exchanger, the welding point should be soaked in water below the welding point, and the plate should be welded with a silver electrode containing 50% silver. It is forbidden to directly weld the plate heat exchanger without taking insulation measures, otherwise the temperature will be too high. After damage, after welding, it must be insulated with insulation board to prevent surface condensation. When installing, the inlet end is at the bottom and the outlet end is at the top.
The compressor of the small constant temperature control system equipment must not be placed horizontally or inverted during the handling of the compressor, otherwise the lubrication performance of the sliding part will be reduced and the compressor will be damaged when it starts. The inclination with respect to the horizontal state shall not exceed 5 degrees, and shall be welded into the system as soon as possible after the rubber stopper is removed, and the time is controlled within 10 minutes. When replacing the capillary, the length of the capillary cannot be increased or decreased arbitrarily, and when the length of the capillary is increased, an unfavorable situation will occur. When the copper tube and the capillary tube are connected, the capillary insertion depth is controlled to be about 10 mm, and the assembly gap of the copper tube brazing is 0.05 to 0.15 mm on one side.
The welded part is very important, and at the same time, it is necessary to pay attention to the strengthening of the process part. The welded part should be found by professional technicians for welding.
Raccomandazioni correlate
-
Environmentally Friendly Cold Plate Freezer
924During the period, we all know that the supervision of environmental protection is springing up, and the editor of cold plate freezer tells everyone that the awareness of environmental protection has spread.According to previously published data, ...
Visualizza i dettagli -
A safe place for cryochillers in the production area
970Cryochiller units are used more frequently in summer. Some manufacturers may replace new equipment, or some companies are just established in the food industry or the chemical industry, and industrial types need cryochiller units to cool down the ...
Visualizza i dettagli -
What Will Happen to the Over-Cooling of the Low Temperature Chiller?
935As we all know, the low temperature chiller is a kind of professional refrigeration design widely used in industry. Although it can provide an effective cryogenic environment, there are some abnormal phenomena in over-refrigeration. Usually, the l...
Visualizza i dettagli -
The Function Introduction of Heating Cooling Translator
995The HR series heating and cooling circulators produced by wuxi guanya can provide the circulation devices of cold source and heat source, with a wide range of work. They are used in pharmaceutical, chemical, biological and other industries, provid...
Visualizza i dettagli