Precauzioni per la manutenzione della saldatura delle apparecchiature del sistema di controllo della temperatura di piccole dimensioni
Piccole apparecchiature di controllo del sistema termostatico prestare attenzione al punto di confronto quando la riparazione, LNEYA produttori professionali ricordato che la parte di saldatura è anche uno dei punti chiave della manutenzione, quindi quali aspetti devono essere...
When the small-scale thermostat control system equipment is welded, protective measures should be taken for the chassis and various components to prevent the flame from being burned by the torch. When welding, pay attention to the adjustment of the torch flame. When the flame is adjusted to the neutral flame, it can be welded. The speed should be as fast as possible to avoid damage to the compressor, the refrigeration valve body and the copper pipe.
If the copper tube is black after soldering, it should be adjusted to increase the flux flow until the copper tube is purple after soldering. When replacing the plate heat exchanger, the welding point should be soaked in water below the welding point, and the plate should be welded with a silver electrode containing 50% silver. It is forbidden to directly weld the plate heat exchanger without taking insulation measures, otherwise the temperature will be too high. After damage, after welding, it must be insulated with insulation board to prevent surface condensation. When installing, the inlet end is at the bottom and the outlet end is at the top.
The compressor of the small constant temperature control system equipment must not be placed horizontally or inverted during the handling of the compressor, otherwise the lubrication performance of the sliding part will be reduced and the compressor will be damaged when it starts. The inclination with respect to the horizontal state shall not exceed 5 degrees, and shall be welded into the system as soon as possible after the rubber stopper is removed, and the time is controlled within 10 minutes. When replacing the capillary, the length of the capillary cannot be increased or decreased arbitrarily, and when the length of the capillary is increased, an unfavorable situation will occur. When the copper tube and the capillary tube are connected, the capillary insertion depth is controlled to be about 10 mm, and the assembly gap of the copper tube brazing is 0.05 to 0.15 mm on one side.
The welded part is very important, and at the same time, it is necessary to pay attention to the strengthening of the process part. The welded part should be found by professional technicians for welding.
Raccomandazioni correlate
-
Various reactors and materials use PLC temperature control system
1812The PLC temperature control system is used for the lifting and constant temperature control of glass reactors, metal reactors and bioreactors, especially for heat exothermic control in the reaction process. The heat transfer oil in the jacket of t...
Visualizza dettagli -
Cosa succede al raffreddamento eccessivo del refrigeratore a bassa temperatura?
1454Come tutti sanno, il refrigeratore a bassa temperatura è un tipo di progetto di refrigerazione professionale ampiamente utilizzato nell'industria. Sebbene sia in grado di fornire un ambiente criogenico efficace, si verificano alcuni fenomeni anomali di sovraraffreddamento. Di solito, il refrigeratore a...
Visualizza dettagli -
Simulazione del controllo della variazione di temperatura nel sistema di termoregolazione del raffreddamento e del riscaldamento della casa.
1314Il sistema di controllo della temperatura di raffreddamento e riscaldamento industriale è un'apparecchiatura di controllo della temperatura utilizzata nel processo di raffreddamento e riscaldamento del bollitore di reazione nell'industria farmaceutica e chimica. Quali sono le caratteristiche delle apparecchiature lneya?...
Visualizza dettagli -
Circa 60p Il consumo energetico del refrigeratore è eccessivo
2035Le prestazioni dei refrigeratori 60p Refrigerated di diversi produttori sono diverse e anche il consumo energetico è diverso. Se il consumo di energia del refrigeratore 60p Refrigerated è troppo elevato, è necessario verificare in tempo se ci sono...
Visualizza dettagli
Refrigeratori industriali LNEYA Produttore Fornitore