Energy-efficient high and low temperature circulation box description
With the efficient development of the pharmaceutical and chemical industry, environmental pollution is also the subject of more attention. To this end, LNEYA actively responds to environmental protection, produces energy-efficient and high-temperature circulating boxes, and saves enterprise costs as much as possible.
The high and low temperature circulation box group reduces the condensation temperature under the premise of evaporation temperature. In order to meet the safety and production requirements of the equipment, the evaporation temperature is lowered to reduce the condensation temperature, so as to ensure the cooling water efficiency and increase the transformation. Adjust the reasonable operation of the chiller equipment. When the equipment is safely operated, the cooling unit operates at 70%-80% load ratio and runs at 100% load, and the power consumption per unit of cooling capacity is smaller. In this way, it is necessary to combine the operation of the water pump and the cooling tower.
Prevent and reduce pipe fouling to improve the heat exchange efficiency of the condenser and evaporator. Replenish water If the water treatment is not good, calcium carbonate and magnesium carbonate produced by the heating of calcium bicarbonate and magnesium bicarbonate will deposit on the pipeline. Decreasing the thermal conductivity, affecting the heat exchange efficiency of the condenser and the evaporator, and greatly increasing the electricity cost of the equipment. In addition to the water treatment technology, it is also possible to use the pipeline automatic cleaning equipment for pipeline cleaning. The high-low temperature cycle box group refrigerator frequency conversion device adjusts the speed of the centrifugal refrigerator compressor. After the low-pressure refrigerant passes through the centrifuge, the pressure rises. The higher the speed of the centrifuge, the higher the pressure rises. In actual operation, most of the equipment is running at a non-full load. A fixed-speed centrifuge wastes energy when the equipment is running at a small load. The variable frequency centrifugal chiller can automatically adjust the compressor speed according to the change of the load, and the energy saving space is relatively large.
These operating instructions can help the high and low temperature circulation box to be more energy efficient and use as much energy consumption as possible.
Raccomandazioni correlate
-
Istruzioni per il funzionamento sicuro del bagno a bassissima temperatura LNEYA
1409I termostati a bassissima temperatura utilizzano un numero maggiore di apparecchiature nell'industria farmaceutica e chimica. All'inizio del nuovo anno, ogni operatore deve prestare attenzione alle operazioni di sicurezza e operare in modo sicuro ed efficiente con i termostati a bass...
Visualizza dettagli -
The benefits of choosing a cryostat
2148The temperature of the effluent of the cryogenic refrigerator is very low, so the carrier medium can not be used for water (the water will freeze when it reaches 0 ° C). At this time, it is necessary to use a brine solution or a glycol solution, a...
Visualizza dettagli -
Semiconductor diffusion furnace configuration temperature control equipment
1635In the semiconductor industry, a diffusion furnace is a device used to manufacture doping layers on the surface of semiconductor materials. It achieves the doping process through high-temperature heating and controlled diffusion atmosphere...
Visualizza dettagli -
What is a circulator for LNEYA?
1593Refrigeration cycle heating machine is the laboratory equipment with heating and refrigeration functions, this instrument uses a number of proprietary technology, high precision of temperature control, mainly used for biological, chemical and othe...
Visualizza dettagli
Refrigeratori industriali LNEYA Produttore Fornitore










