The influence of the evaporator of the semiconductor thermostat on the refrigeration effect
Different models of semiconductor thermostat equipment have different options for evaporation.
According to different models, the choice of evaporator is different. For example, box-type semiconductor thermostat equipment uses water tank coil type evaporator; open semiconductor thermostat equipment and screw type semiconductor thermostat equipment use shell-and-tube evaporator ; For acid and alkali resistant semiconductor thermostat equipment, titanium tube evaporator or stainless steel plate exchanger can be selected. A kind of ice water machine, there are many choices, of course, can also be customized according to user needs.

The factors affecting the evaporation temperature of industrial semiconductor thermostat equipment are as follows:
There is oil in the evaporator pipeline. Under normal circumstances, because the lubricating oil and the refrigerant are mutually soluble, no oil film will be formed on the surface of the heat exchanger. The thermal resistance of the oil film may not be considered, but in the case of additional lubricating oil, the same label as the original one must be selected Lubricating oil to prevent the production of oil film.
The air filter is blocked, and the filter must be replaced regularly to ensure the circulating air volume required by the air conditioner. Dry filter clogged: In order to ensure the normal circulation of the refrigerating agent, the refrigeration system must be kept clean and dry. If the system has impurities, the dryer filter will be clogged and the system will be difficult to supply liquid, which will affect the cooling effect. Too little refrigerant, add refrigerant.
The temperature condition of the evaporator of the semiconductor constant temperature equipment. Under normal circumstances, the outer surface of the evaporator is very cold, and the condensed water drops continuously. The temperature of the inlet and outlet air is large. In abnormal conditions, the surface of the evaporator is not too cold and there is not much dew. , Or without condensation, the sound of refrigerant flowing is very loud, and the temperature difference between the inlet and outlet air is small. The reason is that the amount of refrigerant is insufficient, or the opening degree of the expansion valve is small.
The heat exchanger quality requirements of semiconductor thermostat equipment are very high. When choosing, users can also look at the quality and brand of their heat exchangers. It is recommended to choose a better one.
Raccomandazioni correlate
-
5P hot and cold water machine installation instructions
1019The 5P hot and cold water machine is used in various industries and is used for cold treatment. So what problems do you need during installation and maintenance? If the 5P hot and cold water unit refrigeration compressor unit does not have vibrati...
Visualizza i dettagli -
Precautions for the use of chemical refrigeration and heating circulation systems
1020In chemical production, the reaction will generate heat, which will cause the heat to be uneven. If it is not discharged in time, it will increase the temperature in the kettle and cause danger. The existing heating system of the reactor is relati...
Visualizza i dettagli -
Descrizione del vantaggio del marchio della scatola di prova passo dopo passo
1227La scatola di prova walk-in è sviluppata e prodotta da LNEYA. È specializzata nella tecnologia di produzione farmaceutica e fornisce ai clienti vari modelli di marchi. Presenteremo quindi il prossimo test box di tipo "walk-in". Benvenuti a consultare e imparare.
Visualizza i dettagli -
Start-up work for new energy thermal management
976In the pipeline selection of new energy thermal management, if the use of improper/damaged hoses and/or hose joints will result in injury, the new energy thermal management is limited by the temperature, caliber, installation method, etc. Tube, me...
Visualizza i dettagli