Control method for semiconductor test chiller to meet temperature requirements
The biopharmaceutical field requires high-precision temperature to control the activity of enzymes and the production of products; the chemical industry field requires specific temperatures to make chemical reactions proceed stably; the electronics manufacturing field needs to provide a constant temperature environment for various electronic components to make them stable Work and achieve better performance, such as: quartz crystal oscillator, electronic linear accelerator, etc.
Although there are many domestic manufacturers of temperature control equipment, there are very few semiconductor test chiller independently developed, especially in high-precision measurement and control. Semiconductor test chiller manufacturers have developed a method that takes into account high accuracy, high stability, and wide adjustment. The range of high-power temperature control systems is significant.
There are currently two types of direct cooling and indirect cooling.
The direct cooling method is a method in which the cooling unit directly cools the circulating water. First, the temperature sensor collects the temperature value to the temperature controller, and then after a specific control algorithm, the temperature controller controls the refrigeration unit and the heating unit to perform cooling and heating processes, respectively, so as to control the temperature near the set value. When the temperature of the circulating water deviates from the set value, the control system first performs cooling or heating processing. After the temperature of the circulating water enters the set threshold range, the temperature of the circulating water is gradually stabilized by fine-tuning the cooling and heating power.
The temperature control method directly controls circulating water, has high temperature control accuracy, and can be used under low temperature conditions; the disadvantage is that the system structure and control program are complicated.
The indirect cooling method is generally a temperature adjustment method by adjusting the flow ratios of the circulating water at two different temperatures and mixing to obtain the required water temperature. The mixing process is mainly achieved by adjusting the opening of the electric three-way valve. First, the temperature sensor detects the temperature of the two circulating waters respectively, and transmits the temperature value to the temperature controller, and then the temperature controller controls the opening of the electric three-way valve according to a specific control algorithm, that is, the two different temperature waters are controlled. The mixing ratio is more than the circulating temperature of the required temperature.
Semiconductor test chiller heat exchanger is a widely used indirect cooling device in modern industrial production, which can realize heat transfer between two or more fluids with different temperatures, so that the temperature of high temperature fluid or low temperature fluid can meet the process requirements. During the work of the heat exchanger, different heat exchange power and heat exchange efficiency are achieved by adjusting the flow rate of the medium or refrigerant. This kind of equipment has a large heat exchange power, usually hundreds of kilowatts or more, and is bulky and difficult to integrate and transport.
LNEYA’s LL series is a chiller specially developed for the field of electronics production testing. This equipment is mainly used for cooling the heating part of semiconductor manufacturing equipment, cooling the heating part of laser devices, and analyzing the heating part of detection devices. The latest upgrade is not only for cooling but also for heating. The temperature control range can reach -5 ° C to 85 ° C, which improves the performance of precision cooling water circulation equipment and expands the application range of the equipment.
Raccomandazioni correlate
-
What is the temperature of the cryogenic cooling circulator?
1632The LNEYA cryogenic cooling circulator has a cooling temperature range from -125 degrees to -20 degrees. It adopts a computer cascade temperature controller and a PT100 temperature sensor, and the temperature control accuracy can reach ±0.1 degree...
Visualizza dettagli -
Operation Instructions of Heating Cooling Circulator
1656Heating cooling circulator is a process that refrigerant transfers heat from low temperature state to high temperature state, so that its cooling can reach the state of low temperature environment, thus maintaining the low temperature state and re...
Visualizza dettagli -
Istruzioni di prova per il sistema di controllo della temperatura del riscaldamento frigorifero per il test dell'olio combustibile
1844Il sistema di controllo della temperatura di refrigerazione e riscaldamento può essere testato per diversi progetti durante il funzionamento. Il rilevamento dei diversi progetti è diverso. Tra questi, il sistema di termoregolazione del riscaldamento a refrigerazione per il test dell'olio combustibile è ...
Visualizza dettagli -
Chemical process is inseparable from temperature control
1268Chemical process is inseparable from temperature control
Visualizza dettagli
Refrigeratori industriali LNEYA Produttore Fornitore