Istruzioni per l'installazione del frigorifero a -220 °C
The appearance and weight of different models of -220 °C refrigerator are different, so the installation is also important.
-220 °C refrigerator should be placed indoors, should be placed in a solid and flat place, in order to reduce the vibration during the opening operation, you can put a layer of 12 ~ 20mm damping rubber between the -220 ° C refrigerator chassis and foundation Pads, installed and fixed according to the instructions, generally there will be professional and technical personnel to operate at this time, but also pay attention to the surrounding should have a certain space for operation, inspection, maintenance and use. The tools to be transported can be transported by forklift or by lifting with steel cables. However, we recommend using the latter because it avoids the strong impact during handling and the risk of damage.
The -220 °C refrigerator piping system shall be equipped with auxiliary equipment such as filters, water flow switches and water pressure gauges. The chilled water piping system shall be equipped with auxiliary equipment such as water flow switch, water pressure gauge, thermometer, differential pressure bypass valve and expansion water tank. Be sure to pay attention to the range of the power supply voltage. If the customer’s power supply system is not sufficient, on the one hand, it will not start normally, and then it may cause serious damage to the motor. When wiring installation, be sure to pay attention to the accuracy of the line. If the connection is not correct, it will not operate normally.
No matter where the -220 °C refrigerator is installed, it is recommended to read the instruction manual carefully before installation. If you encounter an installation problem that you do not understand, you can contact the relevant manufacturer’s technical personnel.
Raccomandazioni correlate
-
How to Solve the Problem that Water 10hp Refrigerator Can’t Produce Water
1600Wuxi guanya has cold plate freezer for sale for the industrial cold treatment.Well,how to solve the problem of water outlet fault of 10hp cold plate freezer?Therefore,I have sorted out the relevant solutions for the water outlet fault of 10hp cold...
Visualizza dettagli -
La soluzione alla mancanza di allarme refrigerante del termostato di riscaldamento e raffreddamento completamente chiuso
1919What should I do if the fully enclosed heating and cooling thermostat alarms for lack of refrigerant? I believe that many customers will encounter this problem when they use it. In fact, this is relatively simple. As long as we know the principle ...
Visualizza dettagli -
Metodo di manutenzione giornaliera della macchina a ciclo di raffreddamento e riscaldamento dell'olio di trasferimento di calore
1773La macchina a ciclo di raffreddamento e riscaldamento ad olio termoconduttore è un set di supporto per vari reattori dell'industria farmaceutica e chimica. Il reattore può essere utilizzato per il raffreddamento o il riscaldamento e ha un elevato rapporto di efficienza energetica. Non richiede...
Visualizza dettagli -
Relazione tra scarse prestazioni di refrigerazione e refrigerante in ambienti industriali a basse temperature
1437The effect of the refrigeration system of the low-temperature industrial refrigerator is directly related to the refrigerant. Once the refrigerant leaks, the cooling capacity will be insufficient, so that the suction and exhaust pressures are rela...
Visualizza dettagli
Refrigeratori industriali LNEYA Produttore Fornitore