Precauzioni per l'utilizzo del refrigeratore a ricircolo LNEYA
LNEYA’s low temperature recirculating chiller
can be used with supporting instruments (such as rotary evaporators,
fermentation tanks, chemical reactors, freeze-drying equipment,
biopharmaceutical reactors, etc.), with large cooling capacity and fast speed.
The low-temperature circulating chiller can conduct low-temperature and
constant-temperature experiments in the open cold tank inside the machine, or
circulate the low-temperature liquid outside to cool or keep other equipment at
low temperature. There are many precautions when using low-temperature
recirculating chillers. In order to prevent malfunctions, LNEYA lists the
following precautions for your reference:
1. The installation environment of the
low-temperature recirculating chiller must be dry and ventilated, and there
should be no obstacles around the equipment, otherwise it will affect the
normal use of the equipment.
2. The liquid medium added inside the
low-temperature recirculating chiller is particularly important. The liquid
medium is selected according to different temperatures to add different
mediums. The position of the liquid is also very important. The liquid level of
the medium must be about 30 mm below the edge of the liquid tank, otherwise the
heating device will be damaged after power on.
5. The low-temperature recirculating chiller
must do a good job in daily maintenance work, and must ensure that the
appearance of the equipment is dry and clean. Doing a good job in the
maintenance of the equipment is very important to the service life of the
equipment.
6. After using the low-temperature
recirculating chiller, be sure to turn off the switch button of the equipment
first, and then unplug the power supply. Please do not forcibly unplug the
machine’s power supply during the operation of the machine, as this will cause
great damage to the machine itself.
Raccomandazioni correlate
-
Function of Evaporator in Air Cooled Chiller
1031The air-cooled chiller adopts the air cooling mode, which eliminates the essential cooling tower, cooling water pump and pipeline system of the cooling water system, avoids the condenser scaling and water pipe blockage in areas with poor water qua...
Visualizza i dettagli -
How to Make Ultra Low Temperature Recirculating Chillers More Energy-saving
1046In modern times, environmental protection and energy saving is the development theme, so is the industrial chiller. Then, how to improve your industrial chiller to be more energy conservation? First, to prevent and reduce the pipe scaling of indus...
Visualizza i dettagli -
Uso e manutenzione del sistema di controllo della temperatura in laboratorio/bioingegneria
9291. Read the equipment manual carefully before use, get familiar with the operation process and key instructions, and operate in strict accordance with the conditions specified in the manual. 2. When moving the laboratory/bioengineering temperatur...
Visualizza i dettagli -
A cosa bisogna prestare attenzione quando si aggiunge refrigerante a un refrigeratore raffreddato ad acqua
1121Nella nostra vita, crediamo che tutti abbiano molta familiarità con la refrigerazione. Nel settore della climatizzazione centrale e dei processi di raffreddamento della produzione industriale, i piccoli refrigeratori raffreddati ad acqua sono più comuni. Questa unità è composta da un compressore...
Visualizza i dettagli