Introduzione alla preparazione del funzionamento del refrigeratore a bassa temperatura
Why do low temperature chiller need to be ready for operation? We must be very clear that only when we are ready to check the low temperature chiller can we run the equipment better, can we run it more efficiently.
Before running the refrigeratore a bassa temperatura, we need to check the refrigerant, water and electrical equipment, and check the oil separator liquid level, the correct oil position should be in the oil mirror center line between the line.
Be careful to check that all the pressure gauges for the low temperature chiller are open, and whether the oil thermometer has been inserted with the lubricating oil, and check or open all the valves on the oil road that they should be completely open.
Push the start button, the low temperature chiller starts, and then wait to see whether the oil pump is turning correctly, the oil pressure difference is not low than the surface pressure of 0.05-0.3Mpa, and the pressure difference of the oil filter does not exceed 0.1Mpa. Turn the coupling and operate the energy control valve at the same time, so that the unloading indication goes from 0%–100%, then 100%–0%, then manually stop the oil pump.
Try low temperature chiller with hand disc compressor coupling, no card resistance phenomenon shows the normal state. Open the exhaust valve on the compressor, water supply to the oil cooler, and water temperature depends on the oil temperature (the nozzle oil temperature is better to be 40 –55 c). At the same time, water supply to the condenser and evaporator , finally cover the main motor power supply, and the power lamp is on, then the low temperature chiller can be used normally.
With these detailed preparations, it is certain that the low temperature chiller can be better used to achieve the lowest cost and maximum operational efficiency.
Raccomandazioni correlate
-
The advantages of water cooled chiller you need to know
1602Industrial chillers can be generally divided into water-cooled and air-cooled according to the type of refrigeration. The heat exchange medium of Water Cooled Chillers is water.LNEYA has designed and developed a new type of temperature control equ...
Visualizza dettagli -
Guasti comuni e analisi delle cause dei refrigeratori raffreddati ad aria
1884During the use of air-cooled chiller equipment, it is inevitable to encounter some common faults. Users need to understand the possible causes of faults and make corresponding solutions in time, so as to make the production and operation more stab...
Visualizza dettagli -
Teoria del flusso del ghiaccio, qualità dell'acqua ghiacciata, flusso e pressione della macchina per il ghiaccio.
1305The softening of water is also an important problem in the process of using chillers.The pH value of water also needs to be continuously observed. The optimum pH value should be equal to 7. The pH value greater than 7 will cause terrible corrosion...
Visualizza dettagli -
Piccolo accoppiamento per affrontare l'intasamento da ghiaccio dei refrigeratori a circolazione di liquido ad alta e bassa temperatura
1259Nel funzionamento dei refrigeratori a circolazione di liquido ad alta e bassa temperatura, il blocco del ghiaccio è un guasto relativamente comune. Sulla base dell'esperienza dei produttori del settore, abbiamo raccolto alcuni suggerimenti per affrontare il problema dell'intasamento da ghiaccio. Nelle tubazioni...
Visualizza dettagli
Refrigeratori industriali LNEYA Produttore Fornitore