Operation and Maintenance of Small Water Chiller Units
2. Air-cooled module internal filter, in order to better filter impurities in the water system, the protective plate heat exchanger is generally more than 40 meshes, that is to say, its filter is more dense and finer than other brands. The advantage of this method is that it can filter impurities better, and the disadvantage is that the number of cleaning increases. But compared with the air-cooled module machine, the closed circulating water system can better ensure the cleaning of the water system in the future as long as the filters are cleaned in time during the initial operation.
3. Inspection and cleaning of end filters. Water filters are installed in both air conditioning boxes and fan coil units at the end. These water filters need to be checked and cleaned, which is also an indirect reason affecting the water system and can improve the cooling effect of the end.
4. We can’t start it forcibly. We are used to turning it on when something goes wrong. In fact, it is a serious operation error for water chiller, especially the frequent power failure and reset of the chiller, which results in the failure of protection, just like a car with frequent high water temperature failure and failure to deal with it, which eventually leads to the breakdown.
Our company provides small water chiller units, welcome to buy!
Raccomandazioni correlate
-
Sistema di controllo della temperatura di refrigerazione e riscaldamento per il collaudo di dissipatori di calore sotto vuoto nel settore aerospaziale
1324L'applicazione del sistema di controllo della temperatura di refrigerazione e riscaldamento nei test dei dissipatori di calore in ambiente aerospaziale sotto vuoto è molto critica. Tali apparecchiature sono solitamente utilizzate per simulare test di prestazioni termiche in condizioni di temperatura estrema...
Visualizza dettagli -
ISG/TM Motor Test Cooling System High Voltage Failure and Treatment Measures
1943The ISG/TM motor test cooling system is divided into two types in the industry: air-cooled and water-cooled. The working principle is to first inject a certain amount of water into the water tank in the machine, and then pass the ISG/TM motor test...
Visualizza dettagli -
Metodo di manutenzione del frigorifero a bassissima temperatura a meno 17°C
1676After the long-term use of the ultra-low temperature refrigerator of minus 17 °C, it is necessary to carry out certain maintenance work. If the user does not know how to carry out the maintenance work, you can contact the manufacturer to obtain th...
Visualizza dettagli -
Considerazioni sulla selezione dei lubrificanti refrigerati a bassa temperatura
1986Quando si utilizza un refrigeratore criogenico, si desidera sicuramente conoscere tutti gli aspetti del refrigeratore. Ma una delle cose che richiede l'attenzione di tutti è la scelta del tipo di lubrificante per il refrigeratore, perché ci sono molti fattori che influenzano...
Visualizza dettagli
Refrigeratori industriali LNEYA Produttore Fornitore