Descrizione dell'importanza del funzionamento delle apparecchiature del ciclo a bassa temperatura
L'uso delle apparecchiature per cicli a bassa temperatura è inscindibile dal loro funzionamento standard. Le apparecchiature LNEYA per cicli a bassa temperatura vengono spedite con il relativo manuale di istruzioni e gli utenti possono conoscere in anticipo il loro utilizzo. Il ciclo a bassa tempera...
The low temperature circulation equipment, also known as the low temperature constant temperature bath, is a high precision constant temperature source with its own refrigeration, and has the function of a small chiller. Widely used in petroleum, chemical, metallurgy, pharmaceutical, biochemical, physical properties, testing and chemical analysis and other research departments, institutions of higher learning, factory laboratories and metrological quality inspection departments. According to the different opening size of the low-temperature cycle equipment, the constant temperature experiment can be carried out in the equipment, or it can be connected with other equipment through the hose and used together with the constant temperature source.
Low temperature cycle equipment should be used when the medium is used. When the working temperature of the medium in the equipment is relatively low, an aqueous solution of ethylene glycol or absolute ethanol is generally used. When the working temperature is 5 ° C to 80 ° C, deionized water is generally used. When the operating temperature of the low temperature cycle equipment is 80 ° C to 98 ° C, a 15% glycerin aqueous solution is generally used.
Low-temperature cycle equipment uses working power: 220V/50Hz, the power supply should be greater than the total power of the instrument, the power supply must have a good “grounding” device, use liquid medium in the low-temperature cycle equipment, the liquid level of the medium should be lower than the working table 30mm, Otherwise, the heater will be damaged when the power is turned on. When the temperature is higher than room temperature, please turn off the cooling, and the temperature inside the device can be completely controlled. Do not use ethanol when the temperature of the low-temperature cycle equipment is higher than 30 °C, so as to avoid danger. (Because of the high rate of volatilization at high temperatures, it is prone to danger).
The low-temperature circulation equipment should be placed in a dry and ventilated place, and there is no obstacle in the 300mm around the instrument. When the working temperature of the equipment is high, care should be taken not to open the upper cover, and do not enter the tank to prevent burns. After use, all the switches are turned off, the power is cut off; the cleaning work is done, and the work surface and the operation panel are kept clean.
Different manufacturers may have slightly different differences, so users need to know about the low-temperature cycle equipment they purchased. If you are not sure, you can contact the relevant manufacturers to obtain relevant information.
Raccomandazioni correlate
-
Come ridurre il tasso di guasto del sistema di raffreddamento ad acqua del motore a nuova energia?
1525Il sistema di raffreddamento ad acqua per il test dei motori di nuova energia deve prestare attenzione all'uso durante l'uso, non importa quanto sia buona l'attrezzatura utilizzata per un lungo periodo, alcuni problemi si verificheranno più o meno. Quindi, come possiamo ridurre al minimo il tasso di guasto delle apparecchiature durante l'uso?...
Visualizza dettagli -
-
Quali sono i sistemi di test di potenza per le batterie delle auto a nuova energia?
1520Il sistema di batterie di potenza LNEYA è stato testato per il collaudo delle batterie dei veicoli a nuova energia, ma i moderni veicoli a nuova energia hanno molti tipi di batterie. Quali sono le caratteristiche? La batteria al litio ternaria si riferisce a una batteria al litio in cui...
Visualizza dettagli -
The relationship between vocs adsorption condensing equipment price and configuration
1454The quality of vocs adsorption condensing equipment must be guaranteed. This can be used with confidence. The reason for the power consumption may also be that the gas inhaled by the BITZER compressor allows a certain degree of superheat, but the ...
Visualizza dettagli
Refrigeratori industriali LNEYA Produttore Fornitore










