What are the effects of oil level and oil difference in low temperature chillers?
LNEYA tells you that in addition to the refrigeration system, the lubricating oil system is also an important part, with its own oil storage and special oil cooler.
Oil level
It refers to the level of the lubricant in the oil storage container. The oil storage container of the low temperature chiller is provided with an oil level display device. Generally, the oil level in the oil storage container should be 5 mm below the central horizontal line of the mirror. The purpose of specifying the height of the oil level is to ensure that the amount of oil required to form an oil circuit is sufficient when the pump is in operation. If the oil level is too low, it may cause the pump to be insufficient, causing malfunction or damage to the equipment.
Oil pressure difference
It is the guarantee that the lubricating oil is driven by the oil pump to flow to the working parts in the oil system pipeline to overcome the flow resistance. Without sufficient oil pressure difference, there is no guarantee that the lubricating system of the cold and low temperature chiller has sufficient lubrication and cooling oil and the power required to drive the energy regulating device. Therefore, the low temperature chiller manufacturer reminds that the oil pressure difference of the oil system It must be ensured within a reasonable range so that the moving parts of the unit can be fully lubricated and cooled, and the energy adjustment device can be flexibly operated.
Oil temperature
Oil temperature refers to the temperature of the lubricating oil when the low temperature chiller is working. The temperature of the oil will have an important effect on the viscosity of the lubricant. If the oil temperature is too low, the viscosity of the oil increases, the fluidity decreases, and a uniform oil film is not easily formed, so that the desired lubrication effect cannot be achieved, and the flow speed of the oil is lowered, the lubrication amount is reduced, and the power consumption of the oil pump is reduced. Increase; oil temperature is too high, the viscosity of the oil will drop, the oil film will not reach a certain thickness, so that the running parts are difficult to withstand the necessary working pressure, resulting in deterioration of the lubrication condition, causing the wear of the moving parts to intensify, causing the chiller to malfunction.
Through the above explanation, I believe that everyone understands the impact of oil level and oil difference. In order to better use the low temperature chiller, we still need to know carefully about these operating points!
Raccomandazioni correlate
-
Instructions On Refrigeration Of Low Temperature Chiller Circulating Machine Screw Compressor
2047Due to different compressors, the performance of low temperature chiller circulation machine is also different. Screw compressor is different from the piston compressor, whose structure is more sophisticated. Therefore, if the user needs to choose...
Visualizza dettagli -
The importance of temperature cycle control heating and cooling in the production of API
1982China has become the world's largest supply market for APIs. Most of the APIs and intermediates required by foreign manufacturers are purchased in my country. The drug outsourcing process of most of its preparation products, the production process...
Visualizza dettagli -
Caratteristiche strutturali del refrigeratore a ricircolo industriale
1360Nella reazione chimica, ci sono requisiti rigorosi per la temperatura di reazione. È necessario portare la temperatura a una temperatura appropriata per portare a termine la reazione chimica senza problemi. Dopo la reazione, la temperatura...
Visualizza dettagli -
What is the role of the reactor refrigeration and heating circulator? How to choose?
1602The refrigeration and heating circulator is a device that can provide precise temperature control for the reactor. It can realize heating and cooling functions at the same time. It is suitable for chemical reaction processes that require p...
Visualizza dettagli