How to clean LNEYA low temperature refrigerator?
LNEYA low temperature refrigerators need to be cleaned after a long time of use. So, how should the cleaning be carried out? How to clean it is not wrong?
The low-temperature refrigerator cleaning includes the cleaning of the cooling water system and the cleaning of the chilled water system. The cleaning of the cooling water system is mainly to remove scales such as scale, biological slime and corrosion products from the inner wall of the pipeline and the heat exchange surface of the condenser. The cleaning of the chilled water system is mainly to remove deposits such as biological slime and corrosion products inside the evaporator heat exchange surface, the inner wall of the chilled water pipe, the inner wall of the fan coil and the air conditioning system equipment.
The low-temperature refrigerator is physically cleaned with a wire brush, brushed with a special scraper, and cleaned with a high-pressure water jet. And these methods are mainly applicable to water-cooled condensers and shell-and-tube evaporators. High-pressure water jet cleaning, this method can also be used to clean equipment such as pipes. When cleaning the heat exchanger, the ends of the heat exchanger must be removed, and the heat exchange tubes are washed one by one with a high pressure water gun. For pipes, high pressure water jets with flexible tips can be used for cleaning.
Low-temperature refrigerator chemical cleaning is a method of dissolving, loosening, peeling off or peeling off deposits in a device to be cleaned by the action of a chemical agent. Chemical cleaning is also commonly used in conjunction with physical cleaning. The round robin method is a widely used method. The cleaning equipment is formed into a closed loop by means of a temporary cleaning tank, the cleaning liquid is continuously circulated, and the deposition layer is continuously dissolved and detached by the chemical action and the flushing action of the fresh cleaning liquid.
The cleaning method of LNEYA low-temperature refrigerator is as shown above. If the user has problems in each accessory during the cleaning process, it is recommended to solve it in time.
Raccomandazioni correlate
-
What are the applications of steam circulators in chemical industry?
1511The steam circulator in the chemical industry is a temperature control equipment in the pharmaceutical and chemical industry. When users operate, they need to understand the performance and maintenance knowledge in order to operate the equipment e...
Visualizza dettagli -
The reason why the cooling thermostat Chiller suddenly fails to start
1536If there are any unexpected situations during the use of the cooling thermostat Chiller, it is important to promptly identify the specific reasons before resolving them, in order to effectively address various issues. For example, what is the re...
Visualizza dettagli -
Chip high and low temperature aging test box system design
1688The high and low temperature aging test box of the chip is applied to the high and low temperature test industry of the chip. The design schemes provided by the high and low temperature aging test box manufacturers of different chips are different...
Visualizza dettagli -
Analisi della manutenzione del congelatore senza schermo
2083Il congelatore con apertura a schermo è un tipo di apparecchiatura utilizzata nella lavorazione industriale del freddo. Il produttore del congelatore con apertura a schermo LNEYA ricorda a tutti che se il frigorifero con apertura a schermo viene utilizzato per lungo tempo, è necessario un intervento di manutenzione...
Visualizza dettagli
Refrigeratori industriali LNEYA Produttore Fornitore