Effetto dell'umidità sui refrigeratori da laboratorio
The high humidity reduces the insulation strength of the electrical equipment of the chiller in the laboratory. The moisture in the air adheres to the surface of the insulating material to form condensation, which reduces the insulation resistance of the electrical equipment, and the leakage current of the equipment is greatly increased, resulting in insulation breakdown. Condensation inside the switchgear causes creepage and flashover accidents, resulting in electrical faults.
If the air is not convective, the mold growth will increase rapidly. Therefore, in the case of the same humidity and the same temperature, the indoor equipment is much more severe than the outdoor equipment. The chiller material in the laboratory itself or the surface is dirty, which provides the necessary nutrients for the growth of mold. After the mold is formed, the mold cells contain a large amount of water. When the hyphae are meshed with the surface of the insulator, not only the insulation performance of the product is greatly reduced, but also the appearance and signs of the device are affected. Molds often secrete acidic substances during the metabolism process. The conductive metal and the electrical contact material are caused to form a dark film, resulting in an increase in contact resistance. Especially for the printed circuit board of the chiller of laboratory in Wuxi Guanya LNEYA Constant Temperature Refrigeration Technology Co., Ltd., if it is in such an environment for a long time, it will corrode the circuit, which will reduce the accuracy of the instrument, or cause equipment failure or even burn the instrument.
After the conductive metal and magnetic conductive silicon steel sheet in the electrical equipment are corroded, the performance and service life of the equipment will be seriously reduced. After the relative humidity reaches a certain value, the corrosion of the metal in the test room special test system will suddenly increase. Corrosion causes the metal to lose its proper properties. The heat exchanger of the electrical cabinet isolates the air inside and outside the control box to ensure the air inside the box is clean. It adopts the heat pipe structure design, has high heat exchange capacity, simple structure and convenient maintenance.
The chiller for laboratory use is not used for general temperature control systems. The effect of humidity on its laboratory chiller is relatively large. Therefore, we try to avoid the influence of humidity on the chiller in the laboratory and place it in a special environment.


Raccomandazioni correlate
-
Maintenance for Lubrication System of Water Cooled Chiller Plant
1488Medium-sized low-temperature freezer, refrigeration temperature range from -80 ℃ ~ -30℃, safe, reliable, rapid cooling for the liquid, widely used in petrochemical, medical, pharmaceutical, biochemical and freeze-dried, military and other high-tec...
Visualizza dettagli -
How to Maintain Low Temp Chillers
1453Low temp chiller is a kind of refrigeration mechanical equipment which needs to be used in many industrial production operations. It can provide very good refrigeration technology for different production operations and ensure the smooth progress ...
Visualizza dettagli -
What are the causes of the blockage of the cooler?
1476The LNEYA Chiller Cooler HRT whole system is a closed liquid circulation system with the expansion of container, expansion of the container and the liquid circulation is adiabatic, and do not participate in liquid circulation, only mechanical conn...
Visualizza dettagli -
Workflow and Equipment Composition of Oil Refining and Dewaxing
1579The oil dewaxing process is based on the melting point difference between the wax and the oil and the solubility of the wax in the oil becomes smaller as the temperature decreases, and the crystalline wax is precipitated by cooling. Then through t...
Visualizza dettagli
Refrigeratori industriali LNEYA Produttore Fornitore