What cooling unit is compatible with data center liquid cooling?
Data center liquid cooling usually matches a variety of cooling equipment to achieve efficient heat management and ensure that servers and IT equipment operate within a safe operating temperature range.
Cooling unit for data center liquid cooling:
Cold Plates: directly attached to the CPU, GPU and other heat-generating components of the server, and remove heat through liquid cooling medium.
Immersion Cooling System: directly immerse the server in non-conductive coolant, and exchange heat through direct contact with the liquid, which is suitable for high-density computing environments.
Indirect Contact Liquid Cooling System: heat is exchanged with the coolant inside the server through an intermediary fluid (such as fluorinated liquid) in a heat exchanger outside the server, and then the intermediary fluid is transferred to the external cooling system.
Coolant Distribution Unit (CDU): responsible for the circulation, filtration, pressure control and possible temperature regulation of the coolant, and is the core component of the liquid cooling system.
Heat Exchanger: used to transfer the heat in the coolant to the external cooling medium, such as water or air, including plate, tube or mixed heat exchangers.
Cooling Tower or Dry Cooler: located at the end of the liquid cooling system, used to discharge the accumulated heat in the heat exchanger to the atmosphere, or complete the heat exchange through the air cooling medium in the dry cooler.
Circulation Pump: promotes the circulation of coolant in the system to ensure the efficiency of heat exchange.
Water Treatment System: used to treat and maintain the purity of the coolant to avoid corrosion and microbial growth.
In summary, whether it is liquid cooling or traditional air cooling system, the selection and configuration of data center cooling equipment are determined by comprehensive consideration of factors such as the scale of the data center, energy consumption requirements, regional climate conditions and business needs.
Data Center Liquid Cooling ChillerCold Plate Cooling or Immersion Cooling
Unità di distribuzione del refrigerante (CDU) / Refrigeratore
For Servers Cooling/Rack Cooling CDU will become the mainstream thermal solution in the data center. In general, cooling systems with radiators, fans, air conditioning units, etc. are considered insufficient for CPUs over 300W. To cont…
caricamento...
已经是到最后一篇内容了!
Raccomandazioni correlate
-
What are the installation requirements for lithography chillers?
1076In order to ensure the reliable and normal operation of the chiller of the lithography machine and prevent the failure of the chiller caused by improper water distribution pipeline construction, the following matters should be paid attention to wh...
Visualizza i dettagli -
Memory chip test equipment system program description
1125With the rapid development of the component industry, the memory chip test equipment has also made great progress. So, how much do users know about the memory chip test equipment? In order to simplify the test steps, reduce the complexity of the t...
Visualizza i dettagli -
Description of refrigeration principle in semiconductor wafer temperature control
1238In the operation of the semiconductor wafer temperature control refrigeration system, a state transition of a certain working fluid is used, and the necessary heat Q0 is extracted from the heat source of a lower temperature, and the heat Qk is sen...
Visualizza i dettagli -
Piccolo accoppiamento per affrontare l'intasamento da ghiaccio dei refrigeratori a circolazione di liquido ad alta e bassa temperatura
805Nel funzionamento dei refrigeratori a circolazione di liquido ad alta e bassa temperatura, il blocco del ghiaccio è un guasto relativamente comune. Sulla base dell'esperienza dei produttori del settore, abbiamo raccolto alcuni suggerimenti per affrontare il problema dell'intasamento da ghiaccio. Nelle tubazioni...
Visualizza i dettagli