How to Deal with Fault of Conpressor after Cold Plate Freezer for Sale?
In the operation of the cryogenic refrigerator refrigeration system, once the compressor fault occurs, it will affect the operation of the cryogenic refrigerator. So what are the faults that affect the compressor? How do clients settle it if the compressor fault occurs after cold plate freezer for sale? Before dealing with the compressor fault, we should understand these clearly, as for how to deal with the compressor fault. After the compressor of the cryogenic refrigerator breaks down and the original damaged cryogenic compressor is removed, it requires to carry out nitrogen pollution treatment on system and then connect the new refrigeration compressor system. Next, in order not to generate an oxide film on the inner wall of the copper tube during welding operation, is recommended to inject nitrogenit, and the time for it should be sufficient.
When replacing the compressor of the cryogenic refrigerator, it needs to pay attention not to use the replaced cryogenic refrigerator compressor as a vacuum pump to empty the air in the pipeline of the external machine, otherwise it will burn down the compressor, all uses vacuum pumps for vacuuming. In addition, when the refrigeration compressor is replaced, add an appropriate amount of frozen oil corresponding to the compressor.
When replacing the compressor of the cryogenic refrigerator, attention should be paid to prevent the excessive amount of frozen oil in the system, otherwise, the heat transfer effect of the system will be reduced, resulting in high pressure of the system and damage to the system as well as the compressor.
After the installation of the compressor of the cryogenic refrigerator, it is necessary to check whether the radiator works normally. If the system pressure exceeds the normal pressure (13-15kg), it will cause the clutch to slip, the bearing, the coil can be burnt out or the compressor can be damaged.
After cold plate freezer for sale, the compressor fault is solved and it is installed, at the same time, check whether other accessories are affected during installation and disassembly, and put into operation after confirmation.
Raccomandazioni correlate
-
How To Solve The Electric Vehicle Motor Test Condensation Is Too High?
1721The condensing pressure of the electric vehicle motor test will increase, the compression function will increase, the cooling capacity will decrease, the cooling coefficient will decrease, and the energy consumption will increase. The reason for t...
Visualizza dettagli -
The advantages of water cooled chiller you need to know
1586Industrial chillers can be generally divided into water-cooled and air-cooled according to the type of refrigeration. The heat exchange medium of Water Cooled Chillers is water.LNEYA has designed and developed a new type of temperature control equ...
Visualizza dettagli -
SUNDI Cooling And Heating System-R & D testing of organic synthetic materials and fine chemicals
1788LNEYA's customer is a research institute engaged in the research, development and production of high-performance, environmentally-friendly new organic materials and fine chemicals.The adhesives produced by customers can be used in integrated circu...
Visualizza dettagli -
Relazione tra scarse prestazioni di refrigerazione e refrigerante in ambienti industriali a basse temperature
1432The effect of the refrigeration system of the low-temperature industrial refrigerator is directly related to the refrigerant. Once the refrigerant leaks, the cooling capacity will be insufficient, so that the suction and exhaust pressures are rela...
Visualizza dettagli
Refrigeratori industriali LNEYA Produttore Fornitore