Come scegliere il refrigeratore e la macchina per lo stampaggio a iniezione?
A. First way:
The 1HP water-cooled chiller can be equipped with 80 tons locking force injection moulding machine, and the temperature can be controlled at 5-10 degrees.
The 1HP water-cooled chiller can be equipped with 100 tons mould-locking force injection machine, and the temperature can be controlled at 10-15 degrees.
The 1HP water-cooled chiller can be equipped with 120 tons mould-locking force injection moulding machine, and the temperature can be controlled at 15-20 degrees.
(The matching of air-cooled chiller is 0.8 times that of water-cooled chiller, that is, the temperature of injection moulding machine of 1HP air-cooled chiller with 64 tons of clamping force is controlled at 5-10 degrees.)
B. The second way:
1HP water-cooled chiller can be equipped with injection moulding machine with a single injection volume of 10 QZ, and the temperature can be controlled at 5-10 degrees.
Injection Mold Quantity 1QZ=28.5g
The above formulas are the results summarized by the classics. In addition to the above formulas, the salesman should filter the actual situation and select the appropriate chiller.
C. Matching of chillers and cooling towers:
According to experience, 1HP chiller needs a cooling tower of 1.2 tons to take away the heat generated by the chiller.
Siamo un top chiller manufacturer. Welcome to buy our products.
Raccomandazioni correlate
-
Lista di classificazione delle camere di prova ad alta e bassa temperatura con raffreddamento e riscaldamento alternato
1376Nella scelta della camera di prova alternata per il raffreddamento e il riscaldamento ad alta e bassa temperatura, gli utenti dell'impresa devono avere una certa comprensione della graduatoria delle camere di prova alternate per il raffreddamento e il riscaldamento ad alta e bassa temperatura presenti sul mercato...
Visualizza dettagli -
Treatment of insufficient exhaust gas in high and low temperature impact test chamber compressor
1771The efficiency of the high and low temperature impact test chamber during use is very important. If there is a shortage of high compressor exhaust, we need our LNEYA technicians to solve it in time. So, how to solve it better? The high and low tem...
Visualizza dettagli -
Vocs condensation adsorption technology energy control instructions
1835The vocs condensation adsorption technology has been developed under the current trend of environmental protection. The LNEYA vocs condensation adsorption technology uses condensation adsorption technology. In order to save operating costs, it is ...
Visualizza dettagli -
Refrigeratori industriali LNEYA Produttore Fornitore










