Precautions for operation of ethylene glycol utra-low temperature chiller at minus 30 degrees
The minus 30 degree ethylene glycol utra-low temperature chiller is a device that is used more in the pharmaceutical and chemical industry. When using it, you need to pay attention to its operating specifications to operate it. If used improperly, it will cause a short service life.
Refrigerant leakage will not only affect the refrigeration efficiency of the minus 30 degree ethylene glycol utra-low temperature chiller, but also may affect the health of the personnel entering and leaving the equipment room due to refrigerant leakage, so the refrigerant leakage problem must be paid attention to.
Under normal circumstances, the refrigerant is not a consumable item, so it will not be missing frequently. If it is frequently or suddenly missing, it is recommended to check whether the refrigerant of the minus 30 degree ethylene glycol utra-low temperature chiller has leakage problems. If there is a leakage problem, it should be timely Find the leakage point and make up for the leakage, or replace the relevant refrigerant pipelines and connectors. If necessary, forced ventilation should also be performed.
The second is the load. To put it bluntly, it is not just the load of the compressor. The compressor must be coordinated with the machinery including the condenser, evaporator, expansion valve, etc. to be able to normally cool. In addition, there are water pumps and water towers or air-cooled utra-low temperature chiller. Fan systems, etc., these are compatible with each other. If the load of the utra-low temperature chiller exceeds the standard, it will not just be that the compressor is not enough, and all other parts and components will have the problem of excessive pressure! Larger loads, or exceeding the rated load, will cause overload and will affect more serious problems, including a series of problems such as decreased cooling efficiency, increased noise, increased vibration amplitude, excessive consumption of electrical resources, reduced life, etc. requires attention!
It can be said that the parameters related to temperature and pressure are important parameters of the minus 30 degree ethylene glycol utra-low temperature chiller. Enterprises should pay attention to the parameters related to the temperature and pressure of the equipment, and solve problems in a timely manner. In the process of use, we also need to pay attention to its maintenance and use instructions. Lneya provides minus 30 degrees ethylene glycol utra-low temperature chiller equipment to provide users with professional after-sales service.
Raccomandazioni correlate
-
Precauzioni per il raffreddamento e il riscaldamento durante il funzionamento dei vari reattori
1495In molti laboratori sono indispensabili vari recipienti di reazione di aziende chimiche, la cui temperatura di esercizio è compresa tra -80°C e 250°C. Il reattore di laboratorio funziona a temperatura normale e l'acqua di raffreddamento deve passare...
Visualizza dettagli -
Attrezzatura di prova della batteria dell'automobile di nuova energia per la descrizione della batteria
1482Le materie prime delle batterie al piombo sono facili da ottenere, il prezzo è relativamente basso, le prestazioni di scarica ad alta velocità sono buone, le prestazioni di temperatura sono buone, possono lavorare in un ambiente di -40~+60 °C, adatto per la carica flottante,...
Visualizza dettagli -
Heating and cooling system for chemical reaction kettle reaction process
1786In the process of chemical chemical reaction, material temperature is an important production process parameter. For example, in salt crystallization, solution separation, organic pigment and intermediate processing, temperature control is particu...
Visualizza dettagli -
Considerazioni sulla selezione dei lubrificanti refrigerati a bassa temperatura
1984Quando si utilizza un refrigeratore criogenico, si desidera sicuramente conoscere tutti gli aspetti del refrigeratore. Ma una delle cose che richiede l'attenzione di tutti è la scelta del tipo di lubrificante per il refrigeratore, perché ci sono molti fattori che influenzano...
Visualizza dettagli
Refrigeratori industriali LNEYA Produttore Fornitore