Precautions for operation of ethylene glycol utra-low temperature chiller at minus 30 degrees
The minus 30 degree ethylene glycol utra-low temperature chiller is a device that is used more in the pharmaceutical and chemical industry. When using it, you need to pay attention to its operating specifications to operate it. If used improperly, it will cause a short service life.
Refrigerant leakage will not only affect the refrigeration efficiency of the minus 30 degree ethylene glycol utra-low temperature chiller, but also may affect the health of the personnel entering and leaving the equipment room due to refrigerant leakage, so the refrigerant leakage problem must be paid attention to.
Under normal circumstances, the refrigerant is not a consumable item, so it will not be missing frequently. If it is frequently or suddenly missing, it is recommended to check whether the refrigerant of the minus 30 degree ethylene glycol utra-low temperature chiller has leakage problems. If there is a leakage problem, it should be timely Find the leakage point and make up for the leakage, or replace the relevant refrigerant pipelines and connectors. If necessary, forced ventilation should also be performed.
The second is the load. To put it bluntly, it is not just the load of the compressor. The compressor must be coordinated with the machinery including the condenser, evaporator, expansion valve, etc. to be able to normally cool. In addition, there are water pumps and water towers or air-cooled utra-low temperature chiller. Fan systems, etc., these are compatible with each other. If the load of the utra-low temperature chiller exceeds the standard, it will not just be that the compressor is not enough, and all other parts and components will have the problem of excessive pressure! Larger loads, or exceeding the rated load, will cause overload and will affect more serious problems, including a series of problems such as decreased cooling efficiency, increased noise, increased vibration amplitude, excessive consumption of electrical resources, reduced life, etc. requires attention!
It can be said that the parameters related to temperature and pressure are important parameters of the minus 30 degree ethylene glycol utra-low temperature chiller. Enterprises should pay attention to the parameters related to the temperature and pressure of the equipment, and solve problems in a timely manner. In the process of use, we also need to pay attention to its maintenance and use instructions. Lneya provides minus 30 degrees ethylene glycol utra-low temperature chiller equipment to provide users with professional after-sales service.
Raccomandazioni correlate
-
Temperature control system for reaction kettle
782The reaction kettle temperature control system is an automated equipment used to precisely control the temperature of materials inside the reaction kettle, widely used in fields such as chemical, pharmaceutical, biochemical, and material sci...
Visualizza i dettagli -
Introduction to the quality and configuration of industrial refrigeration and heating circulators
857With the development and progress of society, industrial refrigeration and heating circulators are used more in the industry, and the technological level is becoming more and more complex. So, what should users pay attention to after purchasing th...
Visualizza i dettagli -
High and low temperature hot and cold water cooling machine for battery motor test
1038LNEYA high and low temperature cold and heat integrated water cooler is used in battery thermal management of new energy electric vehicles. The following is the relevant principle applied in thermal management.The high and low temperature cold and...
Visualizza i dettagli -
Vocs gas condensation recovery unit processing instructions
1298With the continuous inspection of environmental protection, Wuxi LNEYA VOCS gas condensation recovery device has also received continuous attention from the public. Most chemical, pharmaceutical and industrial industries are urgently dealing with ...
Visualizza i dettagli