Troubleshoot the main points of failure of the high and low temperature cooling system
When the industrial high and low temperature cooling system is in use, what is the general reason if the temperature cannot drop down? How should we deal with such failures?
Let’s first analyze the principles and methods of industrial cooling. The circulating heat transfer medium is different. Generally, the high and low temperature cooling system industry mostly uses direct cooling, while indirect cooling is used, with plate heat exchangers or oil coolers installed inside. In other devices, the heat medium and cooling water source in the system exchange heat in the heat exchanger to reduce the temperature of the medium.
The temperature of the high and low temperature cooling system cannot be reduced. Generally, we conduct inspection and maintenance from the following aspects:
1. The cooling solenoid valve is damaged: it is necessary to check whether the solenoid valve coil can work normally, if it is damaged, it needs to be replaced; the panel does not output a cooling signal, carefully check the circuit or use the component replacement method to check.
2. Circuit failure: Check the circuit part of the system, the cooling water inlet or outlet pipeline is blocked: check whether the valve in the cooling water pipeline is fully opened, and ensure that the flow and pressure of the cooling water are sufficient, and the heating contactor is stuck, Always heating: observe the pull-in state of the contactor, and worsen damaged electrical parts.
In addition to troubleshooting the above two possible causes of failure, we also need to check whether the cooling plate is replaced or the cooling exchanger is blocked.
The advantage of using indirect cooling is that it has high temperature control accuracy and strong adaptability. It can be applied to the temperature control of high and low temperature cooling system industries. And because the heat transfer medium is cooled first, the cooling impact on the temperature control equipment is relatively small. Of course The disadvantage is that the cooling speed is relatively slow, and the price is more expensive than direct cooling.
Raccomandazioni correlate
-
In che modo la camera di prova a bassissima temperatura controlla l'elettricità statica?
1873Per controllare la qualità statica della camera di prova a bassissima temperatura, la camera di prova a bassissima temperatura deve controllare meglio l'elettricità statica. Come fa la camera di prova a bassissima temperatura LNEYA a controllare l'elettricità statica...
Visualizza dettagli -
Siamo LNEYA, un produttore di refrigeratori di liquido.
1867Il produttore di refrigeratori LNEYA è impegnato nella ricerca e sviluppo, nella produzione e nella vendita di sistemi di termoregolazione per la refrigerazione e il riscaldamento, congelatori a bassissima temperatura, sistemi di collaudo di componenti automobilistici a nuova energia e sistemi a ciclo di riscaldamento. Il ...
Visualizza dettagli -
Informazioni sulle istruzioni per la selezione del refrigerante delle macchine a ciclo ad alta e bassa temperatura
1616Nel funzionamento delle macchine a ciclo ad alta e bassa temperatura, la presenza di refrigerante è essenziale e il refrigerante misto ecologico utilizzato da LNEYA è migliore in termini di prestazioni. La macchina a ciclo ad alta e bassa temperatura...
Visualizza dettagli -
L'uso e le caratteristiche dei circolatori di raffreddamento ad alta e bassa temperatura della serie SUNDI
1794The SUNDI series of high and low temperature cooling circulators are equipment for direct or auxiliary heating in the fields of biology, physics, chemical engineering, medical treatment, environmental protection, etc. Moreover, the temperature con...
Visualizza dettagli
Refrigeratori industriali LNEYA Produttore Fornitore