Quali sono gli effetti del separatore d'olio sull'apparecchiatura analizzata dal produttore del refrigeratore?
Oil separators use more accessories in the
chiller refrigeration system. So as users, we need to understand where the main
impact is in order to better use the equipment.
In the configuration of the chiller, the
position of the oil separator is after the compressor discharge port. After the
compressor, this arrangement is because the refrigerant is mixed with the
refrigerated lubricating oil only after compression in the compressor
compression chamber, and the oil separation operation is required after being
discharged from the compressor. Oil separation is the separation of
refrigerated lubricating oil.
Therefore, the role of the oil separator is
also quite large. Once the chiller manufacturer does not have an oil separator,
it will cause the refrigerated lubricating oil and refrigerant to enter the
condenser together, and the condenser will not work, and the condensation
effect will not be achieved.
The chiller manufacturer tells everyone
that the oil separator has a great effect on the separation of the mixture of
refrigerant and oil, which greatly affects the work of the chiller. If the
separation effect is good, the cooling effect of the entire chiller will be
very good. If the separation effect is poor, the refrigeration effect of the
entire refrigerator will also become poor. This is because once the refrigerant
and lubricating oil cannot be completely separated, a small part of the
lubricating oil will enter the condenser with the refrigerant, resulting in
defects The cooling effect.
Therefore, the existence of the oil
separator still has its effect. Once there is no oil separator, the lubricating
oil will not be recovered, precipitated, cooled and continue to be supplied to
the compressor, and the compressor will lose lubrication, thereby increasing
the gap between the components. Wear and tear improves the heat dissipation and
prevents the compressor from operating normally in a short period of time.
Of course, these chiller manufacturers have
already considered it, so all the parts that should be configured for the
chiller have already been configured.
Raccomandazioni correlate
-
Istruzioni per la manutenzione giornaliera dei circolatori di riscaldamento e raffreddamento
1596Dopo che il circolatore di riscaldamento e raffreddamento ha funzionato a lungo, è necessario eseguire alcuni interventi di manutenzione: a cosa bisogna prestare attenzione? Per garantire il normale funzionamento del circolatore di riscaldamento e raffreddamento dopo l'avvio...
Visualizza dettagli -
Detailed Description of Single-Stack Refrigeration Technology
1902With the continuous development of the times, ultra-low temperature refrigeration technology is also constantly developing. On the list of ultra low temperature freezers, Wuxi Guanya continues to advance in the refrigeration equipment market with ...
Visualizza dettagli -
Detailed Introduction of Air Cooled Chiller Equipment
1626LNEYA refrigeration has accumulated over 10 years of cooling supporting application experience. According to different application fields and service conditions, it has developed a variety of types of cooling chillers, including air cooled chiller...
Visualizza dettagli -
Hybrid car battery test equipment cooling capacity description
1581Due to insufficient insulation thickness of the hybrid vehicle battery test equipment and pipeline or damage to the insulation layer, the loss of cooling capacity is increased, which affects the cooling effect. In the operation of the hybrid vehic...
Visualizza dettagli
Refrigeratori industriali LNEYA Produttore Fornitore