Come risolvere il fenomeno della brinatura del compressore del congelatore da 50p?
Il congelatore 50p è utilizzato nel trattamento industriale a freddo, ma se le prestazioni non sono buone, può portare al lavoro industriale, soprattutto se è difettoso, è più difficile da risolvere. Pertanto, è meglio capire i vari difetti del congelatore 50p...
50p freezer compressor return air frosting is a very common phenomenon in the refrigeration system. Under normal conditions, system problems will not be formed immediately, and the fine frosting will not be treated normally. If the frosting phenomenon is serious, it needs to be solved in time. The root cause of this situation is that the refrigerant flowing through the evaporator does not fully absorb the heat required to expand itself to a predetermined pressure temperature value.
The temperature and pressure volume values that cause the 50p freezer to return to the air are relatively low. This problem may be caused by the evaporator not being able to absorb heat normally, or the cold volume generated by the evaporator cannot be taken away. The representation is that the return liquid temperature and pressure are normal or slightly lower, and the compressor is gradually condensed toward the evaporator from the gas return port. After a long time, all the ice is frozen from the compressor return port to the evaporator and the throttle valve to the evaporator section. , there is a low pressure. Since the amount of refrigerant is too small, the evaporation pressure of the evaporator is low, resulting in low evaporation temperature, which will gradually lead to condensation of the evaporator to form a heat insulation layer and transfer the expansion point to the compressor return air to cause the compressor to return to the air. If the amount of fluorine is normal or excessive, and if there is a situation such as excessive condensation heat exchange, the high pressure is low, then the refrigerant at the front end of the throttle valve under the same volume will show low pressure and high quality.
At the initial throttle opening, the quality of the refrigerant liquid flowing through the throttle valve will be more than normal, and the amount of heat that needs to be absorbed from the evaporator will be excessive. If the corresponding heat is not completely absorbed from the evaporator, the compressor will be returned. The tracheal temperature is low. At the same time, due to the low pressure at the front end of the throttle valve, the back pressure of the throttle valve will also be low. If the Dalian 50p chiller installation system is an expansion valve, (detecting the return pipe temperature and pressure, the pipe temperature is reduced, The pressure reduction opening increases) Compared with the normal state opening, it will not make too much adjustment, then the low pressure will be maintained until the compressor returns to the frost, which seems to be deficient in fluorine (low pressure and low pressure) and low return pipe temperature. Causes frosting.
In operation, users must also recognize the benefits of high-performance 50p freezer for work operation. LNEYA uses high-profile branded accessories to operate equipment more efficiently.

Raccomandazioni correlate
-
The API China exhibition is a direct hit, because of you, the harvest is wonderful!
1116The API China exhibition is a direct hit, because of you, the harvest is wonderful! Golden Autumn OctoberIt’s a good time of the year.The 83rd China International Pharmaceutical Raw Materials / Intermediates / Packaging / Equipment FairIn Nanch...
Visualizza i dettagli -
What are the noise reduction methods for industrial chillers?
960Question: What are the noise reduction methods for industrial chilled water machines? Answer: 1. Industrial industrial chilled water machine axial fan has different noise due to different wings and speed. The noise of octopole electromechanical is...
Visualizza i dettagli -
Detailed introduction of the motor control cooling system Chiller
1271With the continuous development of new energy vehicles, the motor control cooling system Chiller is also under continuous development. The new energy vehicle motor test special chiller can adaptively adjust the cooling capacity of the chiller acco...
Visualizza i dettagli -
Several elements of the operation of -20 degree industrial cryogenic chiller
1224-20 degree industrial cryogenic chiller is a refrigeration equipment that provides low temperature chilled water. It is often used in production enterprises, such as chemical companies, pharmaceutical companies and other production processes, to p...
Visualizza i dettagli