Ricerca nell'intera stazione

Grande refrigeratore d'acqua

  • High Performance and Low Noise

These compressors not only perform excellently but also operate quietly. Even during long-term operation, they can run for over 100,000 hours without failure.

  • Intelligent Temperature Control

The unit features segmented or stepless energy regulation. It adjusts flexibly according to the thermal load requirements during production, ensuring optimal cooling efficiency.

  • Energy-Efficient Control

By using the outlet temperature of the refrigerant as a control point, the unit’s control center adjusts the compressor load by controlling the movement of the energy regulation valve, achieving actual energy savings.

outdoor chillers

Potenza di riscaldamento 3,5kW~15kW

temperature accuracy ±0.3℃

large water chillers

Heating power 2.5kW~10kW

temperature accuracy ±0.3℃

screw water chillers

Circulation Pump MAX 5m³/h~28m³/h 2bar

precisione della temperatura ±0,5

screw chiller plant

Circulation Pump MAX 2.4m³/h~12.1m³/h 2bar

precisione della temperatura ±0,5

water cooled screw chillers

Circulation Pump MAX 2.3m³/h~12m³/h 2bar

precisione della temperatura ±0,5

industrial water coolers

Circulation Pump MAX 2.3m³/h~12m³/h 2bar

precisione della temperatura ±0,5

Modello LG2-75W LG2-100W LG2-140W LG2-180W LG2-230W LG2-280W
Intervallo di temperatura  -25℃~5℃
Capacità di raffreddamento
-20℃
kW 80 111 158 206 259 318
Kcal/hr*10³ 68.8  95.5  135.9  177.2  222.7  273.5 
Potenza 3N/400V/50HZ
Cooling input power at (-20℃) 56 74  105  136  166  205
Compressore Forma semi-closed double screw compressor
Heat control range 25%~100%
Chilled water Forma   Plate, dry, overflow or falling film heat exchanger
Chilled water volumeT/H 24 32  46  59  75  92 
Water pressure drop 40~80
Dimensioni del collegamento DN65 DN80 DN100 DN125
Acqua di raffreddamento Forma Horizontal tubular heat exchanger
Cooling water volumeT/H 26 35 50 65 80 99
Water pressure drop 40~80
Dimensioni del collegamento DN80 DN100 DN125 DN150

LARGE WATER CHILLER ‘S APPLICATIONS

Viene generalmente utilizzato per il raffreddamento delle macchine e dei mandrini nei processi di produzione, per il controllo della temperatura di vari farmaci e processi di preparazione nel campo farmaceutico e per il controllo della temperatura di reazioni chimiche come la cristallizzazione e la sintesi chimica o di laboratorio, nonché per i test sui nuovi veicoli energetici e sui semiconduttori.

Servizio globale

Ha servito più di 30.000 clienti.
Esportato in più di 20 paesi.

Brevetti di certificazione

Ha ottenuto la certificazione CE, la certificazione SGS e la certificazione ISO.

Servizio post-vendita

Fornire una formazione tecnica completa.
Con soluzioni 24/7.

Team di professionisti

Fondata nel 2010, con 15 anni di esperienza nel settore.
20% dei dipendenti sono tecnici.

Controllo qualità

Ispezione visiva.
Test di prestazione.
Test di sicurezza elettrica.

Contattaci subito per avere maggiori dettagli e prezzi sui refrigeratori a coclea.

Intervallo di temperatura
Consider the production temperature requirements first. Different applications (such as air conditioning and low-temperature projects) have different temperature needs.
Cooling Capacity and Single Unit Cooling Capacity
The cooling capacity directly affects the energy efficiency and operating economy. When designing a chiller system, multiple units should be arranged to ensure production continues even if one unit is down.
Energy Consumption
Consider both electrical and steam consumption, especially for large systems. The goal is to maximize energy efficiency by considering the combined use of electricity, heat, and cooling.
Environmental Protection
Focus on the noise level and the impact of the refrigerants on the environment. Avoid using refrigerants that damage the ozone layer or are harmful to the environment, ensuring that the system meets environmental standards.
If you have any doubts about choosing the right chiller, feel free to contact us. Our 24/7 customer service team is available to provide professional consultation and offer custom-designed solutions.

The air cooled screw compressor chiller is mainly composed of the screw compressor, expansion valve, condenser, evaporator, and other components.
Below is the translation of the specific parts and their functions:
Screw Compressor  
It is the power source of the air-cooled screw chiller system. Its main function is to extract the vapor from the evaporator in a timely manner, maintain low temperature and low pressure, and increase the pressure and temperature of the refrigerant vapor through compression, creating conditions for the heat transfer of the refrigerant vapor to the external environment.
Condensatore  
The air-cooled screw chiller uses a finned condenser. The condenser is a heat exchange device that works by transferring the heat of the high-temperature, high-pressure vapor discharged from the compressor to the surrounding cooling medium.
Valvola di espansione  
Since the high-pressure, normal-temperature refrigerant liquid cannot be directly sent into the low-temperature, low-pressure evaporator, it needs to be depressurized and its temperature reduced. Therefore, the expansion valve is used to obtain low-temperature, low-pressure refrigerant, which is then sent to the evaporator to absorb heat and vaporize.
 Evaporatore  
Similar to the condenser, the evaporator is also a heat exchange device. It evaporates the low-temperature, low-pressure refrigerant liquid into vapor, absorbs heat from the cooled medium, reduces the temperature of the cooled medium, and provides low-temperature chilled water to achieve cooling. The evaporator, like the condenser, must have a sufficiently large area to work effectively.

*
*
Invio....
Inviato con successo!
Invio fallito! Riprovare più tardi
Errore e-mail!
Errore telefonico!

Aggiungi il nostro account manager tramite il codice QR qui sotto