Ricerca nell'intera stazione

Industrial heating systems

  • The temperature control accuracy is around 0.5℃.
  • Employ a fuzzy PID adaptive controller
  • The temperature of the heat-conducting medium is fed back through the Pt100 sensor.
  • High-temperature cooling process, continuous heating and cooling can be achieved.
  • A fully enclosed system is equipped with an expansion vessel, which is insulated and does not participate in the liquid circulation.

Lneya’s UC/LY series is an economic type of heating circulators. UC/LY series utilizes industrial heating system. Its maximum cooling capacity is 130kW(UC-A13030N). There are options for air cooling and water cooling available. Lneya’s UC-XX30 series temperature range is +50℃~+300℃, and LY/UC-50XX series temperature range is +50℃~+170℃. UC series can only control the temperature of the heat transfer medium.

Industrial heating systems

50°C

lowest

300°C

Highest

±0.5°C

Precisione del controllo della temperatura


Modello UC-5530N UC-7530N UC-A1030N UC-A1530N UC-A2530N UC-A3830N UC-A6030N UC-A9530N UC-A13030N
Temp  range 50℃~300℃
Temp control Controllo della temperatura di uscita del fluido conduttore di calore
Heating power KW 5,5kW 7,5kW 10kW 15kW 25kW 38kW 60kW 95kW 130kW
Raffreddamento
Capacity
kW at
300℃ 5,5kW 7,5kW 10kW 15kW 25kW 38kW 60kW 95kW 130kW
200℃ 5..5kW 7,5kW 10kW 13kW 25kW 38kW 60kW 95kW 130kW
100℃ 4kW 5kW 7kW 12kW 20kW 30kW 48kW 76kW 100kW
65℃ 1,8kW 2,2kW 3kW 5kW 8,5kW 12kW 19kW 30kW 40kW
Criculation pump
flow
Max35L/min 1,2BAR Max50L/min 1,2BAR Max50L/min 1,2BAR Max110L/min 1,5BAR Max150L/min 1,5BAR Max200L/min 1,5BAR Max250L/min 2,5BAR Max400L/min 2,5BAR Max400L/min 2,5BAR
Dimensioni cm 40*70*130 45*70*160 45*70*160 70*100*175 70*100*175 80*120*185 150*100*185 200*145*205 200*145*205
Power max
AC 380V 50HZ
7kW 9kW 12kW 17kW 28kW 41kW 65kW 101kW 136 kW
Opzionale 220V 60HZ three phase,440V~460V 80HZ three phase

Heat apparatus: provide a heat source and convert electrical energy into thermal energy, and heat the heat-conducting medium.


Circulating Pump: the driving heat-conducting medium circulates within the system to ensure that the heat is uniformly transferred to the target equipment (such as reaction vessels, microchannel reactors, etc.). The circulating pump is resistant to high temperature and corrosion, and its flow rate can be adjusted.

Our standard machine will not alarm. If you have any requirements, we can provide optional configurations.

ProblemsPossible CausesSolutions
Large temperature fluctuationPt100 sensor failureCalibrate or replace the sensor
Abnormal circulation pumpPipe blockage/voltage instabilityClean the pipes or check the power supply
High temperature alarmInsufficient cooling/overload of heaterCheck the cooling water flow or reduce the load

*
*