EER Calculator – How to Calculate Energy Efficiency Ratio
Energy Efficiency Ratio (EER) is a metric used in Imperial units to measure the energy efficiency of cooling equipment , such as refrigeratori industriali, air conditioners, and heat pumps. A higher EER means better cooling performance for the same amount of power consumed. How do you calculate EER?
To make calculations easier, we’ve created an EER calculator. Simply select the correct unit system and enter the value to determine your equipment’s EER. For those interested in manual calculations, we’ve also provided a detailed calculation method below the calculator. We hope this helps.
Energy Efficiency Ratio (EER) Calculator
Enter the values below to calculate EER and the corresponding COP.
BTU/hr
W
How to Calculate Energy Efficiency Ratio
EER is most commonly used in the imperial system. It is defined as the ratio of cooling capacity (BTU/h) to power input (W):
EER = Cooling capacity (BTU/h) ÷ Input power (W)
For example, if a chiller delivers 15,000 BTU/h of cooling and consumes 1500 W of power:
EER = 15,000 BTU/h ÷ 1,500 W = 10 (BTU/h·W).
EER is commonly used for cooling equipment, while COP is also used for heating equipment. So how do we convert COP and EER? Let’s review how to calculate COP:
In the metric system, capacità di raffreddamento is expressed in kilowatts (kW), and COP is the ratio of cooling output to electrical input, both measured in kW.COP is calculated using the metric system:
COP = Cooling capacity (kW) ÷ Input power (kW)
For example, an industrial chiller’s nameplate states a cooling capacity of 80 kW. In one hour, it consumes 20 kW of electricity. Its COP is:
COP = 80 kW ÷ 20 kW = 4.0
This means the unit delivers 4 kW of cooling per 1 kW of electricity consumed.To convert between EER and COP, you need to understand the unit conversion:
1 kW = 1000 W
1 kW = 3412 BTU/h
1 W = 3.412 BTU/h
Therefore:
Cooling capacity (BTU/h) = Cooling capacity (W) × 3.412
So we get:
COP = Cooling capacity (W) ÷ Input power (W)
EER = Cooling capacity (BTU/h) ÷ Input power (W) = Cooling capacity (W) × 3.412 ÷ Input power (W) = COP × 3.412
Thus:
EER = COP × 3.412
COP = EER ÷ 3.412
Examples:
If COP = 3, EER = 3 × 3.412 = 10.236
If EER = 12, COP = 12 ÷ 3.412 ≈ 3.52
Conclusione
We hope this guide helped clarify how EER is calculated.Still have questions? Our team is here to help. Looking for a high-efficiency industrial chiller? LNEYA offers custom chiller with a variety of performance options.
[Contact us now] to get started with your custom solution.

- Chiller Components and Refrigeration Fundamentals Guides
- Chiller Types and Selection Guides
- How Does a Peltier Cooler Work
- Peltier Chiller vs. Compressor Chiller
- Dicembre 2025
- Novembre 2025
- Ottobre 2025
- Settembre 2025
- Agosto 2025
- Luglio 2025
- Giugno 2025
- Maggio 2025
- Marzo 2025
- Febbraio 2025
- Gennaio 2025
- Dicembre 2024
- Novembre 2024
- Ottobre 2024
- Settembre 2024
- Agosto 2024
- Luglio 2024
- Giugno 2024
- Maggio 2024
- Aprile 2024
- Marzo 2024
- Febbraio 2024
- Settembre 2023
- Luglio 2023
- Giugno 2023
- Maggio 2023
- Gennaio 2023
refrigeratore raffreddato ad aria refrigeratore Installazione di un refrigeratore Chiller Maintenance chiller refrigerant refrigeratori Congelatore a freddo refrigeratore di raffreddamento sistema di raffreddamento e riscaldamento cooling system sistema di controllo dinamico della temperatura chiller ad alta efficienza energetica chiller antideflagrante congelatore circolatore di riscaldamento refrigeratore industriale refrigeratori industriali raffreddamento industriale congelatore industriale frigorifero industriale reattore a camicia refrigeratore da laboratorio refrigeratore a bassa temperatura notizie refrigeratore d'olio refrigeratore di processo Prozesskühlung reattore refrigeratore raffreddamento del reattore raffreddamento del reattore riscaldamento riscaldamento del reattore raffreddamento circolatore refrigerato refrigeratore a vite refrigeratore per semiconduttori refrigeratore di prova per semiconduttori sundi tcu controllo della temperatura camera di prova termostato refrigeratore a bassissima temperatura refrigeratore di prova per veicoli refrigeratore d'acqua refrigeratore raffreddato ad acqua
Raffreddatori correlati
CONTATTO
TEL:
EMAIL:
WeChat & WhatsApp:

Wechat QR

Hai una domanda o hai bisogno di un preventivo? Compila il modulo qui sotto e il nostro team ti risponderà entro 24 ore.
Refrigeratori industriali LNEYA Produttore Fornitore