Energy Efficiency Ratio (EER) is a metric used in Imperial units to measure the energy efficiency of cooling equipment , such as refrigeratori industriali, air conditioners, and heat pumps. A higher EER means better cooling performance for the same amount of power consumed. How do you calculate EER?
 
To make calculations easier, we’ve created an EER calculator. Simply select the correct unit system and enter the value to determine your equipment’s EER. For those interested in manual calculations, we’ve also provided a detailed calculation method below the calculator. We hope this helps.

Energy Efficiency Ratio (EER) Calculator

Enter the values below to calculate EER and the corresponding COP.



BTU/hr


W


How to Calculate Energy Efficiency Ratio


EER is most commonly used in the imperial system. It is defined as the ratio of cooling capacity (BTU/h) to power input (W):

EER = Cooling capacity (BTU/h) ÷ Input power (W)

For example, if a chiller delivers 15,000 BTU/h of cooling and consumes 1500 W of power:
EER = 15,000 BTU/h ÷ 1,500 W = 10 (BTU/h·W).
 
EER is commonly used for cooling equipment, while COP is also used for heating equipment. So how do we convert COP and EER? Let’s review how to calculate COP:
 
In the metric system, capacità di raffreddamento is expressed in kilowatts (kW), and COP is the ratio of cooling output to electrical input, both measured in kW.COP is calculated using the metric system:

COP = Cooling capacity (kW) ÷ Input power (kW)

For example, an industrial chiller’s nameplate states a cooling capacity of 80 kW. In one hour, it consumes 20 kW of electricity. Its COP is:
 
COP = 80 kW ÷ 20 kW = 4.0
 
This means the unit delivers 4 kW of cooling per 1 kW of electricity consumed.To convert between EER and COP, you need to understand the unit conversion:

1 kW = 1000 W
1 kW = 3412 BTU/h
1 W = 3.412 BTU/h

Therefore:
Cooling capacity (BTU/h) = Cooling capacity (W) × 3.412
 
 
So we get:
COP = Cooling capacity (W) ÷ Input power (W)
EER = Cooling capacity (BTU/h) ÷ Input power (W) = Cooling capacity (W) × 3.412 ÷ Input power (W) = COP × 3.412
 
Thus:

EER = COP × 3.412
COP = EER ÷ 3.412

Examples:
If COP = 3, EER = 3 × 3.412 = 10.236
If EER = 12, COP = 12 ÷ 3.412 ≈ 3.52

Conclusione


We hope this guide helped clarify how EER is calculated.Still have questions? Our team is here to help. Looking for a high-efficiency industrial chiller? LNEYA offers custom chiller with a variety of performance options.
 
[Contact us now] to get started with your custom solution.

<trp-post-container data-trp-post-id='15162'>How to Calculate Energy Efficiency Ratio</trp-post-container> - chiller EER(images 1)

Blog recenti

Catalogo

Tag

refrigeratore raffreddato ad aria refrigeratore Installazione di un refrigeratore Chiller Maintenance chiller refrigerant refrigeratori Congelatore a freddo refrigeratore di raffreddamento sistema di raffreddamento e riscaldamento cooling system sistema di controllo dinamico della temperatura chiller ad alta efficienza energetica chiller antideflagrante congelatore circolatore di riscaldamento refrigeratore industriale refrigeratori industriali raffreddamento industriale congelatore industriale frigorifero industriale reattore a camicia refrigeratore da laboratorio refrigeratore a bassa temperatura notizie refrigeratore d'olio refrigeratore di processo Prozesskühlung reattore refrigeratore raffreddamento del reattore raffreddamento del reattore riscaldamento riscaldamento del reattore raffreddamento circolatore refrigerato refrigeratore a vite refrigeratore per semiconduttori refrigeratore di prova per semiconduttori sundi tcu controllo della temperatura camera di prova termostato refrigeratore a bassissima temperatura refrigeratore di prova per veicoli refrigeratore d'acqua refrigeratore raffreddato ad acqua

Raffreddatori correlati

CONTATTO

TEL:

EMAIL:

WeChat & WhatsApp:

<trp-post-container data-trp-post-id='15162'>How to Calculate Energy Efficiency Ratio</trp-post-container> - EER Calculator(images 8)
+86 18914253067
Wechat QR
<trp-post-container data-trp-post-id='15162'>How to Calculate Energy Efficiency Ratio</trp-post-container> - Energy Efficiency Ratio(images 9)
+86 18914253067 WhatsApp QR

*
*
*
Submissions in progress….
Presentazione riuscita!
Invio fallito! Riprovare più tardi
Errore e-mail!
Numero di telefono sbagliato!