Characteristics of the evaporator of LNEYA screw chiller
The amount of cooling capacity of the screw chiller is directly related to the energy consumption and operational economics of the entire unit, which is worthy of attention. Especially when designing a cold station, there is no single chiller in the general situation. This is mainly because when the screw chiller fails or is shut down for maintenance, it will not stop production. Instead, the reasonable unit should be selected according to the production situation. The number of units. When the water is filled, install the high-level automatic deflation valve, and only the vent valve of the vent valve of the pump outlet pipe (hereinafter referred to as the spout) is not installed.
When the water pump is turned on, the water flow at the spout is in the state of a musical fountain. The high and low jets slowly bring out the air in the system. As the jet flow becomes higher and more stable, the air in the system is cleaned. When the screw chiller has a flow of up to 6 meters, it will end when the nozzle is no longer dropped. Close the valve at the spout, the pressure at the outlet of the pump is 0.25 MPa, and the chiller is turned on smoothly.

LNEYA screw chiller observes Y-Δ time delay relay, the correct value is 3.5 seconds, the simulation runs, the starting load sequence is: 25% solenoid valve – liquid supply valve, compressor (simultaneous) –50% solenoid valve – 75% electromagnetic Valve – 100% solenoid valve. Observe the Y-Δ start delay time, such as too long or too short, to adjust. Stop process: 100% solenoid valve – 25% solenoid valve – liquid supply valve, compressor (simultaneous) stop. The high and low jets slowly bring out the air inside the system as the jet is getting higher and higher and more stable.
It shows that the air in the system is more clean. When the water flow in the nozzle is as high as 6 meters and no longer falls, the jet will end. Close the valve at the spout, the pressure at the outlet of the pump is 0.25 MPa, and the chiller is turned on smoothly. Thorough inspection of the closed pressure test object: whether the support hanger is stable and firm; whether the connection work of the pipeline has been completed and passed the inspection; the joint of the screw chiller and other parts to be inspected are not painted and insulated; the elevation of the pipeline The slope should be checked and passed. The pressure test table must be inspected.
Raccomandazioni correlate
-
The Effect of Battery Test Temperature Simulation System on Testing Electric/Hybrid Vehicle Cooling
1096In the electric vehicle industry, batteries are an important part of automobiles, and their performance directly affects the performance of hybrid/electric vehicles. For this reason, relevant manufacturers in the market have launched a battery coo...
Visualizza i dettagli -
High temperature fault treatment of temperature shock test equipment
1026The whole function of Wuxi Guanya LNEYA thermal shock test chamber is computer controlled. It is a self-developed software with a good operation interface, which makes the operation and monitoring of the user simpler and more intuitive. The mainte...
Visualizza i dettagli -
Analysis of Common Faults in New Energy Vehicle Power Battery Test System
943If the new energy vehicle power battery pack leaks, the general fault manifestation mode: the meter OK light does not light, the meter prompts to check the power system, the high voltage system leakage fault, disconnect the battery pack and the b...
Visualizza i dettagli -
Prima di avviare i refrigeratori industriali, è necessario eseguire i seguenti lavori
9762. For the compressor unit with water system, carefully check whether the cooling water system and chilled water system have water, and whether the water pressure is normal, whether the pipeline system of cooling water and chilled water is unblock...
Visualizza i dettagli