Quali sono gli effetti di un'interruzione di corrente sulla cella frigorifera ad azoto liquido?
Different industries have different temperature requirements for liquid nitrogen cryogenic cryostats. Of course, there are many types of cryogenic cryostats. The refrigeration methods used in different industries are different. Wuxi Guanya LNEYA uses compressor refrigeration. The cooling effect that can be achieved is almost the same as that of the liquid nitrogen cryogenic cold box.
However, there are still customers who use liquid nitrogen cryogenic cryostats, and customers who encounter a power failure when using liquid nitrogen cryogenic cryostats do not know how to solve them.
One is the frequent power outage. If the power is cut off frequently, the next time the liquid nitrogen cryogenic cryostat is started, there will be some damage to the liquid nitrogen cryogenic cold box. The compressor is out of the working state. This will damage the compressor. If the liquid nitrogen cryogenic low temperature box is not used for a long time, it is also easy to cause the pipeline inside the liquid nitrogen cryogenic cold box to be damaged and the pipeline refrigerant to leak. Obviously, the impact on the liquid nitrogen cryogenic cold box is relatively large, and it is prone to failure.
In two cases, it is not energized for a long time, because it is cold in the northern part of the winter, so many customers cut off the electricity of the liquid nitrogen cryogenic low temperature box. So what can you do in the end? If the liquid nitrogen cryogenic cryostat is not energized for a long time, the refrigerant will be converted from a gaseous state to a liquid state during operation, and it will be very easy to cause damage to the pipeline of the liquid nitrogen cryogenic cryostat, which will lead to leakage. That is, leaking refrigerant.

Then, do not frequently power off, it is very harmful to the liquid nitrogen cryogenic cold box. If there is no power failure when the compressor is not working, if there is a sudden power failure and then the power is turned on immediately when the compressor is working, since the pressure difference between the two ends of the compressor is large, the opportunity is caused. The liquid nitrogen cryogenic cold box has no way to work, so the thermal protection is stopped. If the protection zone of the liquid nitrogen cryogenic cold box is damaged, the motor will be burnt if it is serious.
It seems that this situation is also more complicated. If you feel that the liquid nitrogen is cold and cold, you can also choose Wuxi Guanya LNEYA cryogenic low temperature box or ultra-low temperature freezer, and the cooling effect is better.
Raccomandazioni correlate
-
Ultra Low Temp Chiller Compressor Common Protection Instructions
849The ultra low temp chiller compressor is a relatively important part of all its components. In the course of operation, certain protective devices are needed to help the compressor operate safely. What specific protection? Let's take a look! The m...
Visualizza i dettagli -
Industrial grade heating and cooling system placement attention
1234Industrial-grade heating and cooling system Before the power is turned on, check whether the voltage specified on the nameplate is the same as the household voltage. The same can be used to arrange separate power lines and special sockets for the ...
Visualizza i dettagli -
Temperature control instructions for stainless steel reactors and glass reactors
1158Reactor is a kind of reaction equipment in industrial production. It generally needs to be refrigerated or heated. Whether the temperature is suitable or not directly affects its reaction effect. Therefore, if conditions permit, it is generally e...
Visualizza i dettagli -
When to choose TCU temperature control system?
976First of all, we need to know that the reaction kettle generally needs to carry out the necessary temperature control along with the chemical reaction of the material itself. Through the temperature change of the circulating medium in the jacket ...
Visualizza i dettagli