How to deal with the installation of the hot and cold integrated control machine?
Since the thermocouple’s thermal inertia causes the meter’s indicated value to lag behind the measured temperature, this effect is particularly pronounced when performing rapid measurements. Therefore, thermocouples with thinner thermal electrodes and smaller protective tube diameters should be used whenever possible. The protective tube can even be removed when the temperature measurement environment permits.
In the use of hot and cold integrated control machine, usually use materials with good thermal conductivity, thin tube, small inner diameter protection sleeve, in the more precise temperature measurement, use unprotected sleeved bare wire thermocouple, but thermocouple It is easy to damage and should be corrected and replaced in time.

Due to the measurement lag, the amplitude of the temperature fluctuation detected by the thermocouple is smaller than the amplitude of the furnace temperature fluctuation. In order to accurately measure the temperature, a thermocouple with a small time constant should be selected. The time constant is inversely proportional to the heat transfer coefficient. It is proportional to the diameter of the hot end of the thermocouple, the density of the material, and the specific heat. If the time constant is to be reduced, In addition to the thermal coefficient, the error introduced by the insulation of the cold and heat integrated control machine is poor.
The hot and cold integrated control machine protects the tube and the wire plate from excessive dirt or salt residue, resulting in poor insulation between the thermocouple and the furnace wall, which is more serious at high temperatures, which not only causes the loss of the thermoelectric potential but also introduces interference. The error caused by this can sometimes reach Baidu.
The above installation failures should be avoided as much as possible to reduce the error rate of the integrated heat and cold control machine and save the operating cost of the enterprise.
Raccomandazioni correlate
-
How to choose reactor heating and cooling device?
918When the user selects the heating and cooling device of the reactor, if the heating and cooling device of the reactor is not well understood, it will not know how to start when selecting, so how to choose the heating and cooling of the reactor is ...
Visualizza i dettagli -
Refrigeration heating temperature control system equipment used in hydrothermal reactor
851Refrigeration heating temperature control system can be used in a variety of reactors, reactors, and distillation equipment. Today we will analyze what you need to pay attention to when applying it to a hydrothermal reactor. The heat transfer medi...
Visualizza i dettagli -
Piccolo accoppiamento per affrontare l'intasamento da ghiaccio dei refrigeratori a circolazione di liquido ad alta e bassa temperatura
808Nel funzionamento dei refrigeratori a circolazione di liquido ad alta e bassa temperatura, il blocco del ghiaccio è un guasto relativamente comune. Sulla base dell'esperienza dei produttori del settore, abbiamo raccolto alcuni suggerimenti per affrontare il problema dell'intasamento da ghiaccio. Nelle tubazioni...
Visualizza i dettagli -
Come risolvere il guasto del sistema di controllo automatico della temperatura del reattore?
1155Le prestazioni del sistema di controllo automatico della temperatura del reattore sono molto importanti. Una volta riscontrato un guasto che non può essere avviato, è necessario risolverlo il prima possibile, altrimenti la temperatura incontrollabile influirà sul reattore...
Visualizza i dettagli