What are the common debugging problems in low temperature refrigeration baths?
When the low-temperature cooling bath is in debugging, if the local cooling effect is not good, the system may be blocked by foreign matter or the system design is unreasonable and cannot be adjusted normally. At this time, LNEYA removes foreign matter and thoroughly cleans it to adjust the slope of the pipeline.
When debugging, it is found that the vibration and noise of the pump are large when it is running. It may be that the axial and radial deviation of the coupling is large. It may be that the pump flange is too large and the anchor bolts are unevenly stressed. It is the natural vibration frequency of the pump and the pipeline that cause resonance. At this time, the axial and radial deviation of the coupling are adjusted quickly. Adjust the natural vibration frequency between the pump and the pipe, install the relevant soft joint parts, replace the flange and make the anchor bolts evenly.
During commissioning, it was found that the cooling capacity could not reach the required fixed value. It may be that the cooling tower water temperature did not reach the specified cooling parameter, or the pump output was insufficient, or the condenser isolation gasket was misplaced and could not be cooled, or the pipeline in the condenser was blocked. Repair the cooling tower to meet the water temperature and water requirements, remove foreign matter in the pipeline, and check if the condenser isolation gasket is misaligned.

If the exhaust pressure is too high, it is necessary to pay attention to whether the cooling water is insufficient, whether the condensation in the condenser heat transfer tube is serious, whether the cooling water temperature is too high, whether there is too much air in the system, check the cause, repair the cooling tower, and heat transfer of the condenser. The tube is cleaned to remove air from the system.
If severe frost formation is found, check if the return air filter is clogged, if the exhaust air volume is loose after the fan belt is loose, and if the return air valve is too small, it is recommended to clean the return air filter and adjust the fan belt. Adjust the size of the return air valve.
Common faults encountered in the commissioning of these low-temperature refrigeration baths, we try to check them before debugging, try to avoid these faults.
Raccomandazioni correlate
-
Istruzioni per la manutenzione dell'incubatore di semiconduttori ad alta precisione
1249L'incubatore di semiconduttori ad alta precisione è nello stato dell'evaporatore come refrigerante gassoso; dopo il restringimento adiabatico della macchina di restringimento, diventa uno stato ad alta temperatura e ad alta pressione, e il refrigerante gassoso contratto è...
Visualizza i dettagli -
Metodo di manutenzione giornaliera della macchina a ciclo di raffreddamento e riscaldamento dell'olio di trasferimento di calore
1109La macchina a ciclo di raffreddamento e riscaldamento ad olio termoconduttore è un set di supporto per vari reattori dell'industria farmaceutica e chimica. Il reattore può essere utilizzato per il raffreddamento o il riscaldamento e ha un elevato rapporto di efficienza energetica. Non richiede...
Visualizza i dettagli -
What are the causes of corrosion in industrial chillers / water chillers?
1402Industrial chillers are now widely used in various industries, but as they become more and more widely used, many problems slowly emerge. Corrosion problems are also relatively common. Because everyone does not use the standard and the maintenance...
Visualizza i dettagli -
Cooling method for semiconductor testing chiller to meet temperature control requirements
1270The biopharmaceutical field requires high-precision temperature to control the activity of enzymes and the production of products; the chemical industry field requires specific temperatures to stabilize chemical reactions; the electronic manufact...
Visualizza i dettagli