Low-temperature refrigerator manufacturers’ energy adjustment instructions
The energy regulation of low-temperature refrigerator manufacturers’ equipment during operation is also very important. In order to adapt to the change of energy load, Wuxi Guanya (LNEYA) low-temperature refrigerator manufacturers should pay attention to the energy regulation process.
In order to adapt to the load change of the refrigeration system during the operation of the low-temperature refrigerator manufacturer, the water temperature of the unit still needs to maintain its constant requirements, and the manufacturer will effectively accomplish this task through its energy adjustment. The control system of the -150 low temperature refrigerator manufacturer needs to first detect the water temperature of the unit, compare it with the set value, and then issue an energy adjustment command, which will increase or decrease the cooling capacity of the unit to a certain extent.
The manufacturer and the piston refrigeration compressor are the same. The adjustment of the energy of the equipment during the operation is also effective to adjust the cooling capacity by adjusting the displacement, and the energy of the compressor is mainly used during the operation. Adjustment mechanism to achieve.
The energy adjustment of the manufacturer’s multi-head unit can also be realized directly by increasing or decreasing the number of compressors running. The control program can set the loading sequence of each compressor. Therefore, multi-head low temperature refrigerator manufacturers are more widely used in engineering practice due to their excellent partial load performance. The manufacturer’s compact structure, stable operation, stepless adjustment of cooling capacity, good energy saving and less wearing parts.
The equipment of Wuxi Guanya (LNEYA) low-temperature refrigerator manufacturers is compact in structure and efficient in operation, saving resources to a certain extent.

Raccomandazioni correlate
-
Micro-channel reactor thermostatically controlled air-cooled chiller compressor troubleshooting meth
1207The air-cooled chiller is a temperaturecontrol device that is widely used in the microchannel reactor industry. WuxiGuanya LNEYA has produced a cold and heat source thermostatically controlledair-cooled chiller for the microchannel reactor indu...
Visualizza i dettagli -
What should I pay attention to when the price of 5p refrigeration units is too low?
9455p refrigeration units are commonly used refrigeration equipment in various industries. Users will definitely consider the price factor when they purchase. However, Wuxi Guanya (LNEYA) reminds everyone that there are certain differences between th...
Visualizza i dettagli -
Cooling method for laboratory evaporative instruments in operation
905Choosing the right cooling method for an evaporation experiment can have an unimaginable impact on overall system performance, economy, and efficiency. It is necessary to purchase cooling water circulation machine as supporting equipment. When pu...
Visualizza i dettagli -
What is the lack of oil in the 120-degree ultra-low temperature refrigerator?
1178The compressor of the -120 degree ultra-low temperature refrigerator is a complex component that runs at high speed. In order to ensure sufficient lubrication of the moving parts of the compressor crankshaft, bearings, connecting rods, pistons, et...
Visualizza i dettagli