Precautions for the use of chemical refrigeration and heating circulation systems
In chemical production, the reaction will generate heat, which will cause the heat to be uneven. If it is not discharged in time, it will increase the temperature in the kettle and cause danger. The existing heating system of the reactor is relatively simple, and the process of reducing the temperature in the reactor to room temperature takes a particularly long time, and the heat energy cannot be used rationally, resulting in a waste of some resources. However, if the waste heat is released too much, the overall temperature will drop unstable, and the product quality will be affected. Therefore, it is very important to have a cooling and heating cycle system.

The characteristic of the reactor is that the volume and heat capacity are very large, and endothermic and exothermic reactions can occur at any time, so the entire process time will be lengthened when collecting. When the polymerization reaction occurs in the reactor, the chemical raw materials are changing, which will cause changes in the process and materials, and a series of endothermic and exothermic reactions occur. Therefore, the chemical production itself is very complicated.
Points for attention in the use of chemical refrigeration and heating cycle systems
(1) When the reactor is in operation, it needs to strictly follow the relevant standards to prevent over-temperature and over-pressure.
(2) Strict temperature control in accordance with requirements.
(3) It is necessary to prevent the superposition of temperature difference stress and internal pressure stress to ensure that the equipment does not appear to be strained.
(4) The ratio of ingredients must be strictly controlled to prevent violent reactions.
With the rapid development of society, in order to adapt to the current development needs of the chemical industry, it is necessary to strengthen temperature control in the chemical production process and optimize the design of the temperature control system to ensure that it meets the requirements for use and ensures the normal operation of the equipment.
Raccomandazioni correlate
-
Acquisto di un refrigeratore speciale per la macchina di incisione e precauzioni per il funzionamento
1057Il refrigeratore speciale per la macchina di incisione viene utilizzato per il collaudo di componenti, chip, ecc. Queste industrie sono più uso di supporto, quindi quali aspetti dovrebbero essere prestati attenzione quando si sceglie il refrigeratore per la perforazione macchina di incisione? Cosa devo pagare ...
Visualizza i dettagli -
Purchasing Strategy of Ultra-low Temperature Freezer
922The performance of refrigeration system determines the overall performance. If refrigeration technology is good, excellent refrigeration effect can be achieved quickly. It takes only 4-5 hours on average from room temperature to minus 8 degrees Ce...
Visualizza i dettagli -
Application of refrigeration and heating temperature control system in chemical synthesis
861chemical synthesis cooling heating system temperature control unit
Visualizza i dettagli -
Parameters of small gas condensing liquefaction system
1169During the process of loading and unloading gasoline and refueling vehicles, and collecting high-concentration gas from the chemical plant. One or two methods in the process of adsorption or condensation, or the conversion of oil and gas from a ga...
Visualizza i dettagli