Come evitare un funzionamento errato del termostato di riscaldamento e raffreddamento?
When the user is running the heating and cooling thermostat, the operation needs to follow the instructions, so how to avoid inappropriate operations?
Excellent design of hot and cold thermostat:
The LNEYA heating and cooling thermostat has a multi-functional alarm system and safety functions. It uses plate heat exchangers and pipeline heaters to increase heating and cooling rates. Large touch screen graphics display. The heating and cooling integrated machine uses a magnetic drive pump, so there is no shaft seal leakage problem. , Fully enclosed system, extend the life of the heat transfer liquid, a very wide temperature range, no need to replace the liquid medium.
Wrong operation method of heating and cooling thermostat:
The inlet valve of the condenser on the unit that does not need to be opened is not closed before starting up, causing water channeling. Part of the cooling return water of the heating and cooling thermostat will flow away from the condenser of the unit that is not turned on, reducing the cooling water in the condenser of the running unit. Flow, causing the condensing pressure to rise. The operating current of the host increases. The cooling capacity of the unit drops, and in serious cases, the unit will stop running. It not only wastes electricity, but also reduces the cooling effect, and it is easy to damage the equipment.
Due to the previous misoperation, the condensing pressure of the host and the temperature of the cooling water outlet increased, causing misjudgments to the operator of the integrated machine. It is misunderstood that the amount of cooling water is insufficient and the condenser water inlet valve and the cooling water pump outlet valve are opened, and some also increase the cooling tower fan, which causes the power consumption of the water pump and cooling tower fan to increase. In addition, some users blindly added a cooling water pump. Although adding the cooling water pump can indeed reduce the cooling water temperature and condensing pressure, after all, the electrical energy of a water pump is wasted, so it is a mistake.
The correct operation method of heating and cooling thermostat:
The correct operation method of the heating and cooling thermostat is to close the condenser water inlet valve of the unit that does not need to be operated before starting to prevent water channeling. Turning on the heating and cooling thermostat will run the inlet and outlet valves on the condenser of the unit (generally, the outlet valve is normally open, and the inlet valve is opened and closed as needed, the condenser and evaporator are the same) and the corresponding cooling water pump is turned on. Adjust the inlet and outlet water pressure of the condenser to about 68.6kPa (0.7 kg/cm). If the pointer of the condenser inlet and outlet water pressure gauge swings too much, it indicates that there is air in the cooling water system. The air needs to be exhausted and the pressure gauge indicates normal to continue the next step.
Raccomandazioni correlate
-
Ultra-low temperature bearing cooling equipment Shrink Fit Bearings and Bushings and Pins
1326For the metallurgical industry, the oil pressure system of precision machine tools must use refrigeration to control the oil temperature to stabilize the oil film viscosity so that the machine tool can work normally. If applied to steel products, ...
Visualizza i dettagli -
Measures for stable operation of short-range molecular distiller
868If the short-range molecular distiller is inefficient during operation, it will affect the use of the associated refrigeration heating temperature control system. How does the short-range molecular distiller maintain stable operation? If the steam...
Visualizza i dettagli -
Why does the glass reactor need a heating refrigeration circulator in use?
890The glass vacuum reactor is of double-layer glass design. The inner layer is filled with reaction solvent for stirring reaction, and the interlayer can be connected with different cold and heat sources (freezing liquid, hot water or hot oil) for c...
Visualizza i dettagli -
Selection of Temperature Control System for Laboratory Resin Reaction Kettle
10141. Choose from the quality of the laboratory resin reactor temperature control system: can affect the quality of the laboratory resin reactor temperature control system, may be the use of accessories. There are some small factories on the market t...
Visualizza i dettagli