Precautions for installation of special chiller for new energy testing
The installation of the special chiller for new energy testing is an important link before operation. The quality of the installation is directly related to the operation and operation status of the special chiller for new energy testing. So, what should be paid attention to in the installation of the special chiller for new energy testing?
If the special chiller for new energy test adopts semi-hermetic or fully-hermetic compressor, an oil separator should be installed, and an appropriate amount of oil should be added to the installed oil separator. When the evaporation temperature is lower than -15 degrees, a gas-liquid should be installed. Separator and add appropriate amount of refrigeration oil. Secondly, the compressor base should be installed with a shock-absorbing rubber seat, and the installation of the special chiller for new energy testing should leave a maintenance space to facilitate the observation of the adjustment of instruments and valves.
The high pressure gauge of the special chiller for new energy testing should be installed at the tee of the liquid storage and filling valve. The overall layout of the special chiller for new energy testing is reasonable and the color is the same. The installation structure of each type of unit should be consistent.
When debugging the special chiller for new energy test, it is necessary to pay attention to measuring the power supply voltage, measuring the resistance value of the three windings of the compressor and the insulation of the motor, checking the opening and closing of each valve of the refrigeration system, and pouring the refrigerant into the storage liquid to the standard charge after evacuation. 70%-80% of the filling volume, and then run the compressor, add air from low pressure to enough volume.
After the special chiller for new energy test is turned on, first listen to whether the sound of the compressor is normal, check whether the condenser and air cooler are running normally, and whether the three-phase current of the compressor is stable. After the special chiller for new energy test cools down smoothly, check the exhaust pressure, suction pressure, exhaust temperature, suction temperature, motor temperature, crankcase temperature, and expansion valve temperature in the refrigeration system, and observe the frosting of the evaporator and expansion valve. , observe the oil level and color change of the oil glass. Check whether the sound of the special chiller for new energy testing is abnormal.
Another point is that the special chiller for new energy testing needs to pay more attention to its maintenance knowledge and carry out a lot of related maintenance work.
Raccomandazioni correlate
-
Requisiti per l'installazione dei crio refrigeratori a glicole etilenico
979Dopo l'acquisto di refrigeratori a glicole etilenico con i produttori professionali Wuxi Guanya, i requisiti di installazione saranno inviati agli utenti con l'attrezzatura. Quindi, a cosa bisogna prestare attenzione durante l'installazione di...
Visualizza i dettagli -
Detailed Introduction of Air Cooled Chiller Equipment
1241LNEYA refrigeration has accumulated over 10years of cooling supporting application experience. According to differentapplication fields and service conditions, it has developed a variety of typesof cooling chillers, including air cooled c...
Visualizza i dettagli -
What is the temperature of the cryogenic cooling circulator?
999The LNEYA cryogenic cooling circulator has a cooling temperature range from -125 degrees to -20 degrees. It adopts a computer cascade temperature controller and a PT100 temperature sensor, and the temperature control accuracy can reach ±0.1 degree...
Visualizza i dettagli -
Importance of 200KW freezer maintenance
1054After a long period of operation, some faults may occur, which is relatively large for the freezer, so 200 kW freezer maintenance is very important. A regular maintenance and maintenance 200KW freezer can reduce the company's energy costs. With th...
Visualizza i dettagli