How to choose the chiller for cooling the mixing tank?

Mixing tanks are used in coatings, medicine, building materials, chemicals, pigments, resins, food, scientific research and other industries to stir, mix, blend, and homogenize materials. The mixing tank will generate heat during the mixing process, what cooling is used for the mixing tank? The chiller is a device that can maintain constant temperature, constant temperature and constant flow. Cooling the medium with a stirred tank can help.
1. When the mixing tank needs a temperature range of 5 degrees to 30 degrees, use a high-temperature chiller to cool down the mixing tank. When adding ethylene glycol solution to the high-temperature chiller, the temperature can be -5 degrees.
2. When the mixing tank needs to be controlled within the temperature range of -5 degrees to -35 degrees, a medium temperature chiller is used to cool down the mixing tank. The medium-temperature chiller can use ethylene glycol or brine as the refrigerant. When using brine as the refrigerant, the evaporator needs to be anti-corrosion designed.
3. When the mixing tank needs to be controlled in the temperature range of -40 degrees to -120 degrees, a low-temperature chiller is used to cool down the mixing tank.
Depending on the material requirements of the mixing tank, some of them need to be heated. At this time, a cold and hot water chiller can be used. This is a temperature control device that can both cool down and raise the temperature. The temperature control range is from -120 degrees to 200 degrees.
If the mixing tank is used in an environment containing explosive gas, use an explosion-proof chiller to cool down the mixing tank.
Some of the materials in the mixing tank need to be heated, dried or cooled. The cooling cycle uses water to circulate inside and outside the jacket so that the materials will not form agglomerates or stickiness at a certain temperature. It can also be heated or cooled by adding coils and other forms according to user requirements.
If there are technical requirements for the cooling of the mixing tank, it can be customized according to the actual requirements. Please contact us. LNEYA is a manufacturer with exclusive technology and independent research and development and production of industrial temperature control equipment such as chillers.
Raccomandazioni correlate
-
Istruzioni per il funzionamento sicuro del bagno a bassissima temperatura LNEYA
892I termostati a bassissima temperatura utilizzano un numero maggiore di apparecchiature nell'industria farmaceutica e chimica. All'inizio del nuovo anno, ogni operatore deve prestare attenzione alle operazioni di sicurezza e operare in modo sicuro ed efficiente con i termostati a bass...
Visualizza i dettagli -
Introduzione dei refrigeratori industriali da parte dei produttori del settore
1372Industrial chiller is a kind of industrial cooling equipment, which is mainly used to solve the reaction temperature control problems such as machine overheating caused by industrial production. The common reaction kettle in industrial production ...
Visualizza i dettagli -
Chiller unit for power limit testing of new energy batteries
801Temperature control and heat dissipation: Batteries generate a large amount of heat during high load operation. Excessive temperature not only affects the performance of the battery, but also shortens its service life. T...
Visualizza i dettagli -
What do the LNEYA chiller fault codes mean? What is the solution?
1575Q: What is the fault code of the chiller? Answer: E1 means extremely high indoor temperature alarm, E2 means extremely high temperature alarm, E3 means extremely low temperature alarm, E4 means indoor temperature controller failure, E5 means water...
Visualizza i dettagli