LTS series – LNEYA Air cooled chiller or Water cooled chiller https://www.lneya.com/it Industrial Chillers & Freezers Manufacturer, Dynamic Temperature Control Systems - LNEYA Fri, 23 Feb 2024 02:15:06 +0000 it-IT hourly 1 https://wordpress.org/?v=6.4.3 https://www.lneya.com/wp-content/uploads/2023/05/Lneya-logo-e1683777581854-150x137.png LTS series – LNEYA Air cooled chiller or Water cooled chiller https://www.lneya.com/it 32 32 LTS -20℃~80℃ https://it.lneya.com/special-chiller/lts-20-80.html https://it.lneya.com/special-chiller/lts-20-80.html#respond Wed, 17 May 2023 07:57:33 +0000 https://www.lneya.com/special-chiller/lts-20-80.html
LTS -20℃~80℃

LTS -20℃~80℃ Fluoride cooling and heating system

Temperature control during semiconductor manufacturing
  • Controllo del flusso12L/min~45L/min
  • Internal circulating liquid4L~10L
  • Serbatoio di espansione10L~20L
  • Luogo di origineCina

Download dei dati del prodotto

Parametri dettagliati

ModelloLTS-202LTS-203LTS-204LTS-206LTS-208
LTS-202WLTS-203WLTS-204WLTS-206WLTS-208W
Intervallo di temperatura -20℃~35℃
Precisione del controllo della temperatura±0.1℃  at  -20℃~0℃
Controllo del flusso 7~25L/min12~45L/min
The flow control adopts frequency converter adjustment, and the speed is automatically adjusted according to the feedback signal of the flow sensor. The maximum pressure of the circulating pump is 5bar.
Internal circulating fluid volume4L5L6L8L10L
Volume del vaso di espansione10L10L15L15L20L
Visualizzazione della pressione del sistemaThe pressure of the refrigeration system is realized by a pointer pressure gauge (high pressure, low pressure)
The pressure acquisition outlet position of the circulatory system is detected by a pressure sensor and displayed on the touch screen
ControllorePLC, algoritmo di controllo PID fuzzy, con algoritmo di controllo a cascata
Temperature controlModalità di controllo della temperatura di uscita del fluido di trasferimento del calore
External temperature sensor: (PT100 or 4~20mA or communication setting) control mode (cascade control)
Lettera di accordoInterfaccia Ethernet Protocollo TCP/IP
Interfaccia RS485 protocollo modbus RTU
Internal temperature feedback of equipmentEquipment heat transfer medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, ambient temperature, compressor suction temperature, cooling water temperature (available for water-cooled equipment)
Sistema di circolazione chiusoThe whole system is a fully enclosed system, low temperature does not absorb moisture in the air, does not volatilize the heat transfer medium, and the low temperature automatically supplements the heat transfer medium into the circulation system
CompressoreEmerson Copeland/Danfoss Scroll Flexible Compressor
Pompa di circolazioneMagnetic circulation pump
EvaporatoreScambiatore di calore a piastre
CondensatoreMicro channel condenser (air-cooled)
Plate heat exchanger (water-cooled), special attention: clean factory water is required
Accessori per la refrigerazioneDanfoss/Emerson accessories (filter drier, oil separator, high and low pressure protector, expansion valve)
Pannello operativoSchermo tattile a colori da 7 pollici personalizzato LNEYA, visualizzazione della curva di temperatura
SicurezzaWith self-diagnosis function; phase sequence open-phase protector, refrigerating machine overload protection; high-pressure pressure switch, overload relay, thermal protection device and other security functions.
Dimensioni dell'interfaccia di ingresso e di uscitaZG1/2ZG1/2ZG3/4ZG3/4ZG3/4

Descrizione del prodotto

It is widely used in the semiconductor manufacturing process to control the temperature of the reaction chamber, the temperature of the heat sink, and the temperature control of the non-flammable fluid of the heat transfer medium.

1. The pressure holding test of the medium circulation system is 7 bar.
2. Use high-quality magnetic pump without mechanical shaft seal.
Ottimizzare il campionamento della temperatura e la velocità di risposta, algoritmo di controllo appositamente progettato, in grado di rispondere rapidamente al controllo della temperatura stabile.
4. Enhance the design of the circulating pump capacity to meet the high-lift requirements of the system.
5. Continuous high-temperature cooling technology meets the requirements for stable operation when heat is loaded on the heat sink plate and requires cooling and heating constant temperature control.
6. In view of the volatile characteristics of fluorinated liquid, the joint design and system sealing design are strengthened to ensure the service life of the medium.




Fare clic sul messaggio online per richiedere i dettagli del prodotto
Send us a message about LTS series
Send us a message about LTS series
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

Potreste essere interessati anche a questi prodotti

caricamento...

已经是到最后一篇内容了!

]]>
https://it.lneya.com/special-chiller/lts-20-80.html/feed 0
LTS -40℃~80℃ https://it.lneya.com/special-chiller/lts-40-80.html https://it.lneya.com/special-chiller/lts-40-80.html#respond Wed, 17 May 2023 07:57:28 +0000 https://www.lneya.com/special-chiller/lts-40-80.html
LTS -40℃~80℃

LTS -40℃~35℃

Temperature control during semiconductor manufacturing
  • Controllo del flusso12L/min~45L/min
  • Precisione della temperatura±0.1℃ @40℃~-10℃
  • Internal circulating liquid4L~10L
  • Serbatoio di espansione10L~20L
  • Luogo di origineCina

Download dei dati del prodotto

Parametri dettagliati

Modello
LTS-402
LTS-403
LTS-404
LTS-406
LTS-408
LTS-402W
LTS-403W
LTS-404W
LTS-406W
LTS-408W
Intervallo di temperatura
  -40℃~35℃
Precisione del controllo della temperatura
±0.1℃  -40℃~-10℃
Controllo del flusso 
7~25L/min
12~45L/min
The flow control adopts frequency converter adjustment, and the speed is automatically adjusted according to the feedback signal of the flow sensor. The maximum pressure of the circulating pump is 5bar.
Internal circulating fluid volume
4L
5L
6L
8L
10L
Volume del vaso di espansione
10L
10L
15L
15L
20L
Visualizzazione della pressione del sistema
The pressure of the refrigeration system is realized by a pointer pressure gauge (high pressure, low pressure)
The pressure acquisition outlet position of the circulatory system is detected by a pressure sensor and displayed on the touch screen
Controllore
PLC, algoritmo di controllo PID fuzzy, con algoritmo di controllo a cascata
Temperature control
Modalità di controllo della temperatura di uscita del fluido di trasferimento del calore
External temperature sensor: (PT100 or 4~20mA or communication setting) control mode (cascade control)
Lettera di accordo
Interfaccia Ethernet Protocollo TCP/IP
Interfaccia RS485 protocollo modbus RTU
Internal temperature feedback of equipment
Equipment heat transfer medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, ambient temperature, compressor suction temperature, cooling water temperature (available for water-cooled equipment)
Sistema di circolazione chiuso
The whole system is a fully enclosed system, low temperature does not absorb moisture in the air, does not volatilize the heat transfer medium, and the low temperature automatically supplements the heat transfer medium into the circulation system
Compressore
Emerson Copeland/Danfoss Scroll Flexible Compressor
Pompa di circolazione
Magnetic circulation pump
Evaporatore
Scambiatore di calore a piastre
Condensatore
Micro channel condenser (air-cooled)
Plate heat exchanger (water-cooled), special attention: clean factory water is required
Accessori per la refrigerazione
Danfoss/Emerson accessories (filter drier, oil separator, high and low pressure protector, expansion valve)
Pannello operativo
Wuxi Guanya customized 7-inch color touch screen, temperature curve display\EXCEL data export
Sicurezza
With self-diagnosis function; phase sequence open-phase protector, refrigerating machine overload protection; high-pressure pressure switch, overload relay, thermal protection device and other security functions.
Dimensioni dell'interfaccia di ingresso e di uscita
ZG1/2
ZG1/2
ZG3/4
ZG3/4
ZG3/4

 

Descrizione del prodotto

It is widely used in the semiconductor manufacturing process to control the temperature of the reaction chamber, the temperature of the heat sink, and the temperature control of the non-flammable fluid of the heat transfer medium.

1. The pressure holding test of the medium circulation system is 7 bar.
2. Use high-quality magnetic pump without mechanical shaft seal.
Ottimizzare il campionamento della temperatura e la velocità di risposta, algoritmo di controllo appositamente progettato, in grado di rispondere rapidamente al controllo della temperatura stabile.
4. Enhance the design of the circulating pump capacity to meet the high-lift requirements of the system.
5. Continuous high-temperature cooling technology meets the requirements for stable operation when heat is loaded on the heat sink plate and requires cooling and heating constant temperature control.
6. In view of the volatile characteristics of fluorinated liquid, the joint design and system sealing design are strengthened to ensure the service life of the medium.




Fare clic sul messaggio online per richiedere i dettagli del prodotto
Inviateci un messaggio e vi contatteremo al più presto.
Inviateci un messaggio e vi contatteremo al più presto.
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

Potreste essere interessati anche a questi prodotti

caricamento...

已经是到最后一篇内容了!

]]>
https://it.lneya.com/special-chiller/lts-40-80.html/feed 0
LTS -60℃~80℃ https://it.lneya.com/special-chiller/lts-60-80.html https://it.lneya.com/special-chiller/lts-60-80.html#respond Wed, 17 May 2023 07:57:23 +0000 https://www.lneya.com/special-chiller/lts-60-80.html
LTS -60℃~80℃

LTS -60℃~80℃ Fluoride cooling heating system

Temperature control during semiconductor manufacturing
  • Controllo del flusso12L/min~45L/min
  • Precisione della temperatura±0.1℃ @-60℃~-30℃
  • Internal circulating liquid4L~10L
  • Serbatoio di espansione10L~20L
  • Luogo di origineCina

Download dei dati del prodotto

Parametri dettagliati

Modello LTS-602 LTS-603 LTS-604 LTS-606 LTS-608
LTS-602W LTS-603W LTS-604W LTS-606W LTS-608W
Intervallo di temperatura   -60℃~-20℃
Precisione del controllo della temperatura ±0.1℃  -60℃~-30℃
Controllo del flusso  7~25L/min 12~45L/min
  The flow control adopts frequency converter adjustment, and the speed is automatically adjusted according to the feedback signal of the flow sensor. The maximum pressure of the circulating pump is 5bar.
Internal circulating fluid volume 4L 5L 6L 8L 10L
Volume del vaso di espansione 10L 10L 15L 15L 20L
Visualizzazione della pressione del sistema The pressure of the refrigeration system is realized by a pointer pressure gauge (high pressure, low pressure)
The pressure acquisition outlet position of the circulatory system is detected by a pressure sensor and displayed on the touch screen
Controllore PLC, algoritmo di controllo PID fuzzy, con algoritmo di controllo a cascata
Temperature control Modalità di controllo della temperatura di uscita del fluido di trasferimento del calore
External temperature sensor: (PT100 or 4~20mA or communication setting) control mode (cascade control)
Lettera di accordo Interfaccia Ethernet Protocollo TCP/IP
Interfaccia RS485 protocollo modbus RTU
Internal temperature feedback of equipment Equipment heat transfer medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, ambient temperature, compressor suction temperature, cooling water temperature (available for water-cooled equipment)
Sistema di circolazione chiuso The whole system is a fully enclosed system, low temperature does not absorb moisture in the air, does not volatilize the heat transfer medium, and the low temperature automatically supplements the heat transfer medium into the circulation system
Compressore Emerson Copeland/Danfoss Scroll Flexible Compressor
Pompa di circolazione Magnetic circulation pump
Evaporatore Scambiatore di calore a piastre
Condensatore Micro channel condenser (air-cooled)
Plate heat exchanger (water-cooled), special attention: clean factory water is required
Accessori per la refrigerazione Danfoss/Emerson accessories (filter drier, oil separator, high and low pressure protector, expansion valve)
Pannello operativo Wuxi Guanya customized 7-inch color touch screen, temperature curve display\EXCEL data export
Sicurezza With self-diagnosis function; phase sequence open-phase protector, refrigerating machine overload protection; high-pressure pressure switch, overload relay, thermal protection device and other security functions.
Dimensioni dell'interfaccia di ingresso e di uscita ZG1/2 ZG1/2 ZG3/4 ZG3/4 ZG3/4

Descrizione del prodotto

It is widely used in the semiconductor manufacturing process to control the temperature of the reaction chamber, the temperature of the heat sink, and the temperature control of the non-flammable fluid of the heat transfer medium.

1. The pressure holding test of the medium circulation system is 7 bar.
2. Use high-quality magnetic pump without mechanical shaft seal.
Ottimizzare il campionamento della temperatura e la velocità di risposta, algoritmo di controllo appositamente progettato, in grado di rispondere rapidamente al controllo della temperatura stabile.
4. Enhance the design of the circulating pump capacity to meet the high-lift requirements of the system.
5. Continuous high-temperature cooling technology meets the requirements for stable operation when heat is loaded on the heat sink plate and requires cooling and heating constant temperature control.
6. In view of the volatile characteristics of fluorinated liquid, the joint design and system sealing design are strengthened to ensure the service life of the medium.




Fare clic sul messaggio online per richiedere i dettagli del prodotto
Inviateci un messaggio e vi contatteremo al più presto.
Inviateci un messaggio e vi contatteremo al più presto.
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

Potreste essere interessati anche a questi prodotti

caricamento...

已经是到最后一篇内容了!

]]>
https://it.lneya.com/special-chiller/lts-60-80.html/feed 0
LTS -80℃~80℃ https://it.lneya.com/special-chiller/lts-80-80.html https://it.lneya.com/special-chiller/lts-80-80.html#respond Wed, 17 May 2023 07:57:19 +0000 https://www.lneya.com/special-chiller/lts-80-80.html
LTS -80℃~80℃

LTS -80℃~80℃ Fluoride cooling heating system

Temperature control during semiconductor manufacturing
  • Controllo del flusso12L/min~45L/min
  • Precisione della temperatura±0.1℃ @-60℃~-30℃
  • Internal circulating liquid4L~10L
  • Serbatoio di espansione10L~20L
  • Luogo di origineCina

Download dei dati del prodotto

Product Parameters

Modello LTS-802 LTS-803 LTS-804 LTS-806 LTS-808
  LTS-802W LTS-803W LTS-804W LTS-806W LTS-808W
Intervallo di temperatura   -80℃~-20℃
Precisione del controllo della temperatura ±0.1℃  -80℃~-50℃
Controllo del flusso  7~25L/min 12~45L/min
  The flow control adopts frequency converter adjustment, and the speed is automatically adjusted according to the feedback signal of the flow sensor. The maximum pressure of the circulating pump is 5bar.
Internal circulating fluid volume 4L 5L 6L 8L 10L
Volume del vaso di espansione 10L 10L 15L 15L 20L
Visualizzazione della pressione del sistema The pressure of the refrigeration system is realized by a pointer pressure gauge (high pressure, low pressure)
  The pressure acquisition outlet position of the circulatory system is detected by a pressure sensor and displayed on the touch screen
Controllore PLC Siemens, algoritmo di controllo Fuzzy PID con algoritmo di controllo a cascata.
Temperature control Modalità di controllo della temperatura di uscita del fluido di trasferimento del calore
  External temperature sensor: (PT100 or 4~20mA or communication setting) control mode (cascade control)
Lettera di accordo Interfaccia Ethernet Protocollo TCP/IP
Interfaccia RS485 protocollo modbus RTU
Internal temperature feedback of equipment Equipment heat transfer medium outlet temperature, medium inlet temperature, refrigeration system condensation temperature, ambient temperature, compressor suction temperature, cooling water temperature (available for water-cooled equipment)
Sistema di circolazione chiuso The whole system is a fully enclosed system, low temperature does not absorb moisture in the air, does not volatilize the heat transfer medium, and the low temperature automatically supplements the heat transfer medium into the circulation system
Compressore Emerson Copeland/Danfoss Scroll Flexible Compressor
Pompa di circolazione German brand magnetic circulation pump
Evaporatore Adopt Danfoss/Gaoli plate heat exchanger
Condensatore Micro channel condenser (air-cooled)
Plate heat exchanger (water-cooled), special attention: clean factory water is required
Accessori per la refrigerazione Danfoss/Emerson accessories (filter drier, oil separator, high and low pressure protector, expansion valve)
Pannello operativo Wuxi Guanya customized 7-inch color touch screen, temperature curve display\EXCEL data export
Sicurezza With self-diagnosis function; phase sequence open-phase protector, refrigerating machine overload protection; high-pressure pressure switch, overload relay, thermal protection device and other security functions.
Dimensioni dell'interfaccia di ingresso e di uscita G1/2 G1/2 G3/4 G3/4 G3/4

Descrizione del prodotto

It is widely used in the semiconductor manufacturing process to control the temperature of the reaction chamber, the temperature of the heat sink, and the temperature control of the non-flammable fluid of the heat transfer medium.

1. The pressure holding test of the medium circulation system is 7 bar.
2. Use high-quality magnetic pump without mechanical shaft seal.
Ottimizzare il campionamento della temperatura e la velocità di risposta, algoritmo di controllo appositamente progettato, in grado di rispondere rapidamente al controllo della temperatura stabile.
4. Enhance the design of the circulating pump capacity to meet the high-lift requirements of the system.
5. Continuous high-temperature cooling technology meets the requirements for stable operation when heat is loaded on the heat sink plate and requires cooling and heating constant temperature control.
6. In view of the volatile characteristics of fluorinated liquid, the joint design and system sealing design are strengthened to ensure the service life of the medium.




Fare clic sul messaggio online per richiedere i dettagli del prodotto
Inviateci un messaggio e vi contatteremo al più presto.
Inviateci un messaggio e vi contatteremo al più presto.
*
*
正在提交中....
提交成功!
提交失败!请稍后再试
邮箱错误!
电话错误!

Potreste essere interessati anche a questi prodotti

caricamento...

已经是到最后一篇内容了!

]]>
https://it.lneya.com/special-chiller/lts-80-80.html/feed 0