Ricerca nell'intera stazione

Refrigeratori da laboratorio

LTZ 5℃~30℃ low temperature 50 ton chillers

I refrigeratori da laboratorio LNEYA sono disponibili in due tipologie: raffreddati ad aria e ad acqua. Possono garantire un funzionamento continuo 24 ore su 24.

<trp-post-container data-trp-post-id='13129'>laboratory chillers</trp-post-container>(images 1)
<trp-post-container data-trp-post-id='13129'>laboratory chillers</trp-post-container>(images 2)
Capacità di raffreddamento 23kW~155kW
<trp-post-container data-trp-post-id='13129'>laboratory chillers</trp-post-container>(images 3)
Pompa di circolazione MAX
28m³/h
<trp-post-container data-trp-post-id='13129'>laboratory chillers</trp-post-container>(images 4)
Temperature accuracy ±0.5℃
<trp-post-container data-trp-post-id='13129'>laboratory chillers</trp-post-container>(images 5)
Potenza AC400V/AC460V

While the LTZ-+5~30 model only supports a temperature control range of +5°C to +30°C, we can customize units to meet various temperature requirements. LNEYA offers temperature control solutions from -150°C to +350°C.

I refrigeratori da laboratorio LNEYA sono ampiamente utilizzati in vari settori e laboratori grazie alla loro capacità di fornire un raffreddamento preciso e costante. Questi sistemi fanno circolare il refrigerante (solitamente acqua o una miscela di acqua e glicole) per mantenere temperature stabili in applicazioni come il raffreddamento di apparecchiature, il raffreddamento di processo e la ricerca scientifica.

LTz series

5°C

il più basso

30°C

il più alto

±0.5°C

Precisione del controllo della temperatura


Modello LTZ-6
LTZ-6W
LTZ-10
LTZ-10W
LTZ-15
LTZ-15W
LTZ-20W LTZ-30W LTZ-40W
Intervallo di temperatura 5℃~30℃
Cooling capacity 20℃ 23kW 40kW 58kW 79kW 110kW 155kW
Pompa di circolazione MAX 5m³/h 5m³/h 11m³/h 14m³/h 19m³/h 28m³/h
2bar 2bar 2bar 2bar 2bar 2bar
Refrigerante R134A/R407C/R448A R410A/R134A/R448A
Potenza 400V 50HZ  / 460V 60HZ

Feedback sulla temperatura

Feedback di temperatura PT100 (temperatura di ingresso, temperatura di uscita)


Compressore

Highly, Mitsubishi, Panasonic e altri compressori


Protocollo di comunicazione

Protocollo MODBUS RTU Interfaccia RS485



LNEYA never disappoints users!

Vantaggi di Refrigeratori da laboratorio

Controllo preciso: I refrigeratori da laboratorio utilizzano un sistema di controllo della temperatura PID per regolare la temperatura dell'acqua, garantendo un controllo preciso della temperatura.
Efficienza energeticaI refrigeratori da laboratorio utilizzano tecnologie di refrigerazione avanzate e design a risparmio energetico, offrendo un'elevata efficienza energetica. Sono in genere dotati di compressori a frequenza variabile e scambiatori di calore ottimizzati per ridurre al minimo il consumo energetico.
Gestione intelligenteI nostri refrigeratori da laboratorio sono spesso dotati di sistemi di controllo intelligenti, in grado di monitorare in tempo reale la temperatura, la pressione e altri parametri.

<trp-post-container data-trp-post-id='13129'>laboratory chillers</trp-post-container>(images 16)
<trp-post-container data-trp-post-id='13129'>laboratory chillers</trp-post-container>(images 17)
<trp-post-container data-trp-post-id='13129'>laboratory chillers</trp-post-container>(images 18)
LNEYA never disappoints users!

Applicazione di refrigeratori da laboratorio

Per il raffreddamento di fluidi in circolazione in processi o apparecchiature esterne. Mantengono temperature costanti anche in applicazioni con carichi termici elevati e sono adatti a una varietà di processi di laboratorio e industriali.
I refrigeratori d'acqua da laboratorio possono essere utilizzati anche nelle camere bianche per garantire che la temperatura e l'umidità della stanza soddisfino requisiti rigorosi senza compromettere i risultati sperimentali.
Reazioni chimicheMolte reazioni chimiche dipendono dalla temperatura e un controllo preciso è fondamentale per ottenere risultati accurati.

<trp-post-container data-trp-post-id='13129'>laboratory chillers</trp-post-container>(images 19)
refrigeratori a glicole

Potenza di riscaldamento 3,5kW~15kW

temperature accuracy ±0.3℃

<trp-post-container data-trp-post-id='13129'>laboratory chillers</trp-post-container>(images 20)
refrigeratori di fluidi

Potenza di riscaldamento 2,5kW~10kW

temperature accuracy ±0.3℃

<trp-post-container data-trp-post-id='13129'>laboratory chillers</trp-post-container>(images 21)
refrigeratori da laboratorio

Circulation Pump MAX 5m³/h~28m³/h 2bar

temperature accuracy ±0.5℃

<trp-post-container data-trp-post-id='13129'>laboratory chillers</trp-post-container>(images 22)
refrigeratori sotto zero

Circulation Pump MAX 2.5m³/h~15m³/h 2bar

<trp-post-container data-trp-post-id='13129'>laboratory chillers</trp-post-container>(images 23)
refrigeratori di refrigerante

Circulation Pump MAX 1.5m³/h~7.7m³/h 2bar

temperature accuracy ±0.5℃

LTZ9 chiller
refrigeratori raffreddati ad aria

Circulation Pump MAX 2.4m³/h~12.1m³/h 2bar

temperature accuracy ±0.5℃

refrigeratori portatili
refrigeratori raffreddati ad acqua

Circulation Pump MAX 2.3m³/h~12m³/h 2bar

temperature accuracy ±0.5℃

<trp-post-container data-trp-post-id='13129'>laboratory chillers</trp-post-container>(images 26)
refrigeratori criogenici

Circulation Pump MAX 20L/min~40L/min 2bar

temperature accuracy ±0.5℃

LNEYA è il produttore affidabile di refrigeratori da laboratorio

Ogni modello di refrigeratore è certificato secondo gli standard qualitativi internazionali ISO 9001:2008 e la certificazione CE UE, a garanzia di sicurezza e affidabilità.

<trp-post-container data-trp-post-id='13129'>laboratory chillers</trp-post-container>(images 31)

Servizio globale

Abbiamo servito più di 30.000 clienti.
Esportato in oltre 20 paesi.

<trp-post-container data-trp-post-id='13129'>laboratory chillers</trp-post-container>(images 32)

Brevetti di certificazione

Ha ottenuto la certificazione CE, la certificazione SGS e la certificazione ISO.

<trp-post-container data-trp-post-id='13129'>laboratory chillers</trp-post-container>(images 33)

Assistenza post-vendita

Fornire una formazione tecnica completa.
Con soluzioni 24/7.

<trp-post-container data-trp-post-id='13129'>laboratory chillers</trp-post-container>(images 34)

Team professionale

Fondata nel 2010, con 15 anni di esperienza nel settore.
Il 20% dei dipendenti sono tecnici.

<trp-post-container data-trp-post-id='13129'>laboratory chillers</trp-post-container>(images 35)

Controllo qualità

Ispezione visiva
Test di prestazione.
Test di sicurezza elettrica.

Regolazione precisa della temperatura, efficienza energetica e servizio post-vendita senza pensieri

Scegliere il giusto chiller per laboratorio è fondamentale per garantire l'efficienza e l'efficacia dei processi sensibili alla temperatura. Quando si seleziona un chiller, i fattori da considerare includono l'intervallo di temperatura richiesto, la capacità di raffreddamento, il tipo di refrigerante e i requisiti specifici dell'applicazione. Inoltre, l'efficienza energetica, l'impatto ambientale, la facilità d'uso e la manutenzione dovrebbero essere presi in considerazione.
Se non sei sicuro su quale chiller sia il migliore per la tua applicazione, sentiti libero di contattarci! LNEYA offre servizi di consulenza gratuiti e soluzioni personalizzate per soddisfare tutte le tue esigenze.

La manutenzione adeguata è essenziale per garantire prestazioni ottimali e prolungare la vita utile delle attrezzature di refrigerazione da laboratorio. I principali suggerimenti per la manutenzione includono: Pulizia regolare: Pulire regolarmente l’attrezzatura, in particolare le bobine e i filtri, per garantire uno scambio termico efficiente e prevenire l’accumulo di polvere. Ispezione di guarnizioni e tenute: Controllare le guarnizioni per garantire la tenuta e impedire che l’aria calda influisca sul controllo della temperatura. Calibrazione: Calibrare regolarmente il sistema di controllo della temperatura per garantire precisione e affidabilità. Programma di manutenzione preventiva: L’implementazione di un programma di manutenzione preventiva aiuta a identificare e risolvere i problemi prima che provochino guasti all’attrezzatura.

*
*
Submitting….
Inviato con successo!
Invio fallito! Riprovare più tardi
Errore e-mail!
Errore telefonico!